Product Model
FLT 35 CTRL-0.9/I/50

Selling Points
- 1Robust Surge Protection: Provides up to 35 kA of nominal discharge surge current to safeguard against lightning strikes.
- 2Compact Design: Measuring 17.7 mm in width and 65.5 mm in height, ideal for DIN rail mounting in industrial settings.
- 3High Operating Voltage: Supports nominal voltage of 230 V AC and maximum continuous operating voltage of 260 V AC.
- 4Fast Response Time: Offers response times of ≤100 ns to quickly mitigate electrical surges.
- 5Compliance and Safety: Meets IEC 61643-1 and DIN VDE 0675-6 standards, ensuring WEEE/RoHS compliance for environmental safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Combination type | IEC test classification | I
T1 |
EN type | T1 | Type | DIN rail module, one-piece |
Surge protection fault message | optical | Nominal frequency f | 50 Hz
60 Hz |
Nominal voltage U | 230 V AC | Connection method | Screw connection |
Screw thread | M5 | Tightening torque, min | 4.5 Nm |
Stripping length | 14.5 mm | Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 25 mm² | Conductor cross section, rigid min. | 0.5 mm² |
Conductor cross section, rigid max. | 35 mm² | Flammability rating according to UL 94 | V0 |
Open side panel | No | Direction of action | 1L-N/PE |
Nominal frequency f | 50 Hz
60 Hz | Maximum continuous voltage U | 260 V AC |
Maximum continuous operating voltage U | 260 V AC | Maximum continuous operating voltage U | 260 V AC |
Residual current I | ≤ 2.5 mA | Operating effective current I | ≤ 2.5 mA |
Nominal discharge current I | 35 kA | Nominal discharge current I | 35 kA |
Nominal discharge current I | 35 kA | Impulse discharge current (10/350) µs, charge | 17.5 As |
Impulse discharge current (10/350) µs, specific energy | 305 kJ/Ω | Impulse discharge current (10/350) µs, peak value l | 35 kA |
Follow current quenching capacity I | 3 kA | Follow current quenching capacity I | 3 kA |
Voltage protection level U | ≤ 0.9 kV | Voltage protection level U | ≤ 0.9 kV |
Voltage protection level U | ≤ 0.9 kV | Response time t | ≤ 100 ns |
Response time t | ≤ 100 ns | Response time t | ≤ 100 ns |
Max. backup fuse with branch wiring | 125 A (gL) | Degree of protection | IP20 |
Standards/regulations | IEC 61643-1
E DIN VDE 0675-6
E DIN VDE 0675-6/A1
E DIN VDE 0675-6/A2
IEC 61312-1 |
Specifications may be subject to change without notice