Product Model

FLT-CP-3S-350/VZ

In Stock
Last updated: 2025/4/17
Phoenix Contact FLT-CP-3S-350/VZ

Selling Points

  • 125 kA (L-N), 100 kA (N-PE) for effective surge protection.
  • 2Type 1+2 arrester combination, compliant with AEC principle and Class I+II standards.
  • 3Compatible with 230/400 V AC networks, ensuring high continuous voltage of 350 V AC.
  • 4Optical and mechanical status indication for individual arresters, ensuring real-time monitoring.
  • 5Made from PBT housing material, withstanding ambient temperatures from -40 °C to 80 °C.
Product Details
FLT-CP-3S-350/VZ
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
IEC test classification
I
EN type
T1
Type
DIN rail module, two-section, divisible
Number of positions
4
Surge protection fault message
Optical, remote indicator contact
Arrester can be tested with CHECKMASTER from software version:
From SW rev. 3.00
Overvoltage category
III
Pollution degree
2
Nominal frequency f
50 Hz 60 Hz
Nominal voltage U
240 V AC (L-N) 415 V AC (L-L)
Connection name
Remote fault indicator contact
Maximum operating voltage U
250 V AC
Maximum operating voltage U
125 V DC
Max. operating current I
1 A AC (inductive) 1 A AC (ohmic) 30 mA DC (inductive) 200 mA DC (ohmic)
Min. permissible switching capacity
0.12 VA (12 V, 10 mA)
Connection method
Screw terminal blocks
Screw thread
M5
Tightening torque, min
4.5 Nm
Stripping length
18 mm
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
25 mm²
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
35 mm²
Connection method
Plug-in/screw connection via COMBICON
Screw thread
M2
Tightening torque, min
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible min.
0.14 mm²
Conductor cross section flexible max.
1.5 mm²
Conductor cross section, rigid min.
0.14 mm²
Conductor cross section, rigid max.
1.5 mm²
Width
142.8 mm
Height
95.8 mm
Depth
70 mm
Horizontal pitch
8 Div.
Flammability rating according to UL 94
V0
Housing material
PBT
Open side panel
No
Direction of action
3L-N & N-PE
Nominal frequency f
50 Hz 60 Hz
Maximum continuous operating voltage U
350 V AC
Maximum continuous operating voltage U
350 V AC
Rated load current I
125 A
Residual current I
≤ 5 µA (Residual current I
Nominal discharge current I
25 kA (1 channel)
Nominal discharge current I
100 kA
Follow current quenching capacity I
3 kA (effective 264 V)
Follow current interrupt rating I
100 A (effective 350 V)
Voltage protection level U
≤ 1.5 kV
Voltage protection level U
≤ 1.5 kV
Response time t
≤ 100 ns
Response time t
≤ 100 ns
Response time t
≤ 100 ns
Max. backup fuse with branch wiring
315 A (gL/gG, 125 A with serial through wiring)
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 80 °C
Standards/regulations
DIN VDE 0110-1 / IEC 60664-1 / IEC 61643-1
Standards/regulations
IEC 61643-1 EN 61643-11 UL 1449 IEEE C62.1 IEEE C62.34 IEEE C62.45
Mounting type
DIN rail: 35 mm

Specifications may be subject to change without notice