Phoenix Contact FLT-CP-PLUS-1C-350

Selling Points

  • 1High Continuous Voltage: Protects against high voltage fluctuations in 230/400 V AC networks.
  • 2Optical and Mechanical Status Indication: Provides clear visual and mechanical status indicators for each arrester.
  • 3Thermal Disconnect Device: Ensures thermal disconnect for each individual plug, enhancing safety.
  • 4Compact Design: Slim and application-oriented installation blocks for easy integration.
  • 5Compliance with International Standards: Meets IEC, VDE, and UL specifications for robust protection.
Product Details
FLT-CP-PLUS-1C-350
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Combination type
IEC test classification
I / II T1 / T2
EN type
T1 / T2
IEC power supply system
TN-C TT
Type
DIN rail module, two-section, divisible
Number of positions
1
Surge protection fault message
Optical, remote indicator contact
Overvoltage category
III
Pollution degree
2
Nominal frequency f
50 Hz (60 Hz)
Connection name
Remote fault indicator contact
Switching function
Changeover contact
Operating voltage
12 V AC ... 250 V AC 125 V DC (200 mA DC)
Operating current
10 mA AC ... 1 A AC 1 A DC (30 V DC)
Connection method
Screw terminal blocks
Screw thread
M5
Tightening torque
4.5 Nm
Stripping length
18 mm
Conductor cross section flexible
2.5 mm² ... 25 mm²
Conductor cross section rigid
2.5 mm² ... 35 mm²
Conductor cross section AWG
13 ... 2
Connection method
Plug-in/screw connection via COMBICON
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
Conductor cross section rigid
0.14 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Width
35.6 mm
Height
95 mm
Depth
71.5 mm
Horizontal pitch
2 Div.
Flammability rating according to UL 94
V-0
CTI value of material
600
Insulating material
PA 6.6/PBT
Material group
I
Housing material
PBT
Open side panel
No
Mode of protection
L-PEN
Direction of action
1L-N/PE
Nominal voltage U
240 V AC (TN-C) 240 V AC (TT)
Nominal frequency f
50 Hz (60 Hz)
Maximum continuous voltage U
350 V AC
Rated load current I
125 A (< 55 °C)
Nominal discharge current I
25 kA
Maximum discharge current I
50 kA
Impulse discharge current (10/350) µs, charge
12.5 As
Impulse discharge current (10/350) µs, specific energy
160 kJ/Ω
Impulse discharge current (10/350) µs, peak value l
25 kA
Follow current interrupt rating I
50 kA
Short-circuit current rating I
50 kA
Voltage protection level U
≤ 1.5 kV
Residual voltage U
≤ 1.5 kV (at I
Front of wave sparkover voltage at 6 kV (1.2/50) µs
≤ 1.5 kV
TOV behavior at U
415 V AC (5 s / withstand mode) 457 V AC (120 min / withstand mode)
Response time t
≤ 100 ns
Max. backup fuse with V-type through wiring
125 A (gG)
Max. backup fuse with branch wiring
315 A (gG)
Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (amsl)
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (5 - 500 Hz/2.5 h/X, Y, Z)
Maximum continuous operating voltage MCOV (L-G)
528 V AC
Nominal discharge current I
20 kA
Mode of protection
L-G
Nominal voltage
240 V AC
Power distribution system
Single phase
Nominal frequency
50/60 Hz
Measured limiting voltage MLV (L-G)
1350 V
Follow current (N-G)
10 kA (264 V AC)
SPD Type
4CA
Operating voltage
125 V AC
AC operating current
1 A AC
Tightening torque
40 lb
Conductor cross section AWG
12 ... 2
Standards/regulations
EN 60664-1 / IEC 60664-1 / IEC 61643-11
Standards/specifications
IEC 61643-11
Note
2011
Standards/specifications
EN 61643-11
Note
2012
Mounting type
DIN rail: 35 mm

Specifications may be subject to change without notice