Product Model
IB IL 24/48 DOR 2/W-PAC

Selling Points
- 1Designed for robust performance in industrial environments.
- 2Suitable for a wide range of control and protection applications.
- 3Space-saving dimensions for easy integration into various systems.
- 4Simple voltage jumper for supply voltage adjustment (7.5 V DC or 24 V DC).
- 5Maximum current draw of 30 mA for energy efficiency.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 12.2 mm | Height | 119.8 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Note on application | Only for industrial use | Number of interfaces | 2 |
Connection method | Inline data jumper | Transmission speed | 500 kbps |
ID code (dec.) | 189 | ID code (hex) | BD |
Length code (hex) | C2 | Length code (dec) | 194 |
Process data channel | 2 bit | Input address area | 0 bit |
Output address area | 2 bit | Register length | 2 bit |
Required parameter data | 3 Byte | Required configuration data | 4 Byte |
Number of outputs | 2 (floating) | Connection method | Spring-cage connection |
Contact switching type | Changeover contact | Switching voltage | min. 10 mV (DC)
max. 30 V AC (PELV (EN 61131))
max. 60 V DC (PELV (EN 61131)) |
Switching current | min. 10 µA
max. 2 A (30 V DC)
max. 1 A (60 V DC) | Switching capacity | 60 W
62 VA (ohmic) |
Limiting continuous current | 2 A (at maximum ambient temperature) | Mechanical service life | 2x 10 |
Product type | I/O component | Product family | Inline |
Type | modular | Scope of delivery | including Inline connector and labeling field |
No. of channels | 2 | Operating mode | Process data mode with 2 bits |
Special properties | for switching ohmic loads | Article revision | 05 |
Overvoltage category | II (IEC 60664-1, EN 60664-1) | Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Maximum power dissipation for nominal condition | 0.8 W | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 30 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 4 A |
Test voltage: Relay contact / Bus logics | 1.5 kV, 50 Hz, 1 min | Test voltage: Contact/contact | 1 kV, 50 Hz, 1 min |
Test voltage: Contact/functional ground | 1 kV, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice