Product Model
IB IL 24 DI 16-PAC

Selling Points
- 1Connects up to 16 digital sensors with 2 and 3-wire technology.
- 2Efficiently transmits data at 500 kbps for smooth operations.
- 3Ensures reliable performance in harsh environments with IP20 protection.
- 4Operates within a stable voltage range of 19.2 to 30V DC.
- 5Measures 48.8x140.5x71.5mm for easy integration into inline stations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 48.8 mm | Height | 140.5 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Note on application | Only for industrial use | CCCex note | Use in potentially explosive areas is not permitted in China. |
Number of interfaces | 2 | Connection method | Inline data jumper |
Transmission speed | 500 kbps | ID code (dec.) | 190 |
ID code (hex) | BE | Length code (hex) | 01 |
Length code (dec) | 01 | Process data channel | 16 bit |
Input address area | 2 Byte | Output address area | 0 Byte |
Register length | 16 bit | Required parameter data | 1 Byte |
Required configuration data | 4 Byte | Input name | Digital inputs |
Description of the input | EN 61131-2 type 1 | Number of inputs | 16 |
Connection method | Spring-cage connection | Connection technology | 3-conductor |
Input voltage | 24 V DC | Input voltage range "0" signal | -3 V DC ... 5 V DC |
Input voltage range "1" signal | 15 V DC ... 30 V DC | Nominal input voltage U | 24 V DC |
Nominal input current at U | min. 3 mA (at nominal voltage) | Sensor current per channel | max. 250 mA |
Typical response time | < 1 ms | Delay at signal change from 0 to 1 | 1 ms |
Delay at signal change from 1 to 0 | 1 ms | Product type | I/O component |
Product family | Inline | Type | modular |
Scope of delivery | including Inline connectors and marking fields | No. of channels | 16 |
Operating mode | Process data mode with one word | Article revision | 12 |
Overvoltage category | II (IEC 60664-1, EN 60664-1) | Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Maximum power dissipation for nominal condition | 1.6 W | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 60 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 4 A
0 A (without sensors) |
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V supply (bus logic)/functional ground | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |