Product Model
IB IL 24 DO 4

Selling Points
- 1High-Reliability Terminal Block: Designed for industrial use with robust construction and reliable performance.
- 24 Digital Outputs: Connect actuators in 2- and 3-conductor technology for versatile signal output.
- 3Overload Protection: Short-circuit and overload-protected outputs ensure safe operation.
- 4Compact Design: Dimensions 140.5 x 12.2 x 71.5 mm, perfect for DIN rail mounting.
- 5German Engineering: Manufactured in Germany with high-quality materials and precise engineering.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Type | modular | No. of channels | 4 |
Diagnostics messages | Short-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module | ID code (dec.) | 189 |
ID code (hex) | BD | Length code (hex) | 41 |
Length code (dec) | 65 | Process data channel | 4 bit |
Input address area | 0 Byte | Output address area | 4 bit |
Register length | 4 bit | Required parameter data | 3 Byte |
Required configuration data | 4 Byte | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 44 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 2 A |
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min |
Output name | Digital outputs | Connection method | Spring-cage connection |
Connection technology | 2-, 3-conductor | Number of outputs | 4 |
Protective circuit | Overload protection, short-circuit protection of outputs; electronic | Output voltage | 24 V DC (U |
Limitation of the voltage induced on circuit interruption | -46 V ... -15 V | Maximum output current per channel | 500 mA |
Maximum output current per module | 2 A | Nominal output voltage | 24 V DC (voltage difference at I |
Output voltage when switched off | max. 2 V | Output current when switched off | max. 300 µA |
Nominal load, inductive | 12 VA (1.2 H, 50 Ω) | Nominal load, lamp | 12 W |
Nominal load, ohmic | 12 W (48 Ω) | Maximum operating frequency with ohmic nominal load | max. 300 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used) |
Reverse voltage resistance to short pulses | Reverse voltage proof | Behavior with overload | Auto restart |
Behavior with inductive overload | Output can be destroyed | Behavior at voltage switch-off | The output follows the power supply without delay |
Overcurrent shut-down | min. 0.7 A | Output current with ground connection interrupt when switched off | max. 25 mA |
Connection method | Spring-cage connection | Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Connection method | Inline data jumper | Transmission speed | 500 kbps |
Diagnostics | Short-circuit or overload of the digital outputs | Message | Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module |
Width | 12.2 mm | Height | 119.8 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Color | green | Ambient temperature (operation) | -25 °C ... 55 °C |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice