Product Model

IB IL 24 DO 8-PAC

In Stock
Last updated: 2025/4/17
Phoenix Contact IB IL 24 DO 8-PAC

Selling Points

  • 1Manage multiple signal outputs simultaneously for complex operations.
  • 2Withstands continuous industrial use while maintaining accuracy and performance.
  • 3Supports 2, 3, and 4-wire technology for versatile actuator connections.
  • 4Local diagnostic and status indicators ensure real-time monitoring.
  • 5Meets stringent industry standards for digital output modules in safety-related applications.
Product Details
IB IL 24 DO 8-PAC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
48.8 mm
Height
119.8 mm
Depth
71.5 mm
Note on dimensions
Housing dimensions
Note on application
Only for industrial use
CCCex note
Use in potentially explosive areas is not permitted in China.
Number of interfaces
2
Connection method
Inline data jumper
Transmission speed
500 kbps
ID code (dec.)
189
ID code (hex)
BD
Length code (hex)
81
Length code (dec)
129
Process data channel
8 bit
Input address area
0 Byte
Output address area
1 Byte
Register length
8 bit
Required parameter data
3 Byte
Required configuration data
4 Byte
Output name
Digital outputs
Connection method
Spring-cage connection
Connection technology
4-conductor
Number of outputs
8
Protective circuit
Overload protection, short-circuit protection of outputs
Output voltage
24 V (U
Maximum output current per channel
500 mA
Maximum output current per module
4 A
Nominal output voltage
24 V DC (voltage difference at I
Nominal load, inductive
12 W
Nominal load, lamp
12 W
Nominal load, ohmic
12 VA
Behavior with overload
Auto restart
Behavior with inductive overload
Output can be destroyed
Behavior at voltage switch-off
The output follows the power supply without delay
Product type
I/O component
Product family
Inline
Type
modular
Scope of delivery
including Inline connectors and marking fields
No. of channels
8
Operating mode
Process data mode with one byte
Diagnostics messages
Short-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module
Article revision
13
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
1.8 W
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 60 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 4 A
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)
500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (I/O) / functional ground
500 V AC, 50 Hz, 1 min
Connection name
Inline connector
Connection method
Spring-cage connection
Conductor cross section rigid
0.08 mm² ... 1.5 mm²
Conductor cross section flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice