Product Model
IB IL 24 PSDO 4/4-PAC

Selling Points
- 1High Safety Integrity: Achieves SIL 3 according to IEC 61508 and EN 62061, and PL e according to EN ISO 13849-1.
- 2Flexible Transmission Speed: Set to 500 kbps or 2 Mbps using a switch for uniform transmission within a station.
- 3Robust Design: IP20 degree of protection ensures reliable operation in industrial environments.
- 4Versatile Outputs: Includes one positive and one negative switching output each, parameterizable for various applications.
- 5Easy Integration: Compatible with INTERBUS-Safety and PROFIsafe systems, ideal for safety-critical applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 48.8 mm | Height | 119.8 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Note on application | Only for industrial use | No. of channels | 2 |
Connection method | Inline data jumper | Transmission speed | 500 kbps / 2 Mbps (can be switched) |
ID code (dec.) | 167 | ID code (hex) | A7 |
Length code (hex) | 04 | Length code (dec) | 04 |
Process data channel | 8 Byte | Input address area | 8 Byte ((Operating mode: SafetyBridge)) |
Output address area | 8 Byte ((Operating mode: SafetyBridge)) | Register length | 8 Byte |
Required parameter data | 1 Byte ((Operating mode: SafetyBridge)) | Required configuration data | 5 Byte ((Operating mode: SafetyBridge)) |
Output name | Digital outputs | Output description | +/- switching |
Connection method | Spring-cage connection | Connection technology | 2-, 3-conductor |
Number of outputs | 4 (for 2-channel assignment, +/- switching)
4 (for 1-channel assignment, + switching)
4 | Protective circuit | Overload protection, short-circuit protection of outputs |
Output voltage | 24 V DC (U | Output current | max. 3 A (Total current of all outputs) |
Maximum output current per channel | 2 A | Maximum output current per module | 3 A (See technical data) |
Nominal output voltage | 24 V DC | Behavior with inductive overload | Output can be destroyed |
Product type | I/O component | Product family | Inline |
Application | Functional safety | Type | modular |
Diagnostics messages | Short-circuit or overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor | Article revision | 08 |
Maximum power dissipation for nominal condition | 78 W | Transmission medium | Copper |
Supply voltage | 7.5 V DC (see safety data) | Current draw | max. 230 mA |
Supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 3.03 A
typ. 30 mA (all outputs set including actuator current) | Supply voltage | 24 V |
Supply voltage | 24 V DC (via voltage jumper) | Supply voltage range | 19.2 V DC ... 30 V DC |
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min |
Connection name | Inline connector | pluggable | yes |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² | Conductor cross section AWG | 24 ... 16 |
Connection method | Spring-cage connection | Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² | Conductor cross section AWG | 24 ... 16 |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) | Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 70 °C | Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice