Product Model

IB IL 24 SDI 8-PAC

In Stock
Last updated: 2025/4/23
Phoenix Contact IB IL 24 SDI 8-PAC

Selling Points

  • 1The module offers 8 safe digital inputs for single-channel assignment, ensuring reliable and secure data transmission.
  • 2Set the transmission speed to 500 kbaud or 2 Mbaud using a switch, accommodating various system requirements.
  • 3Built with IP20 protection, the module is designed for use in SafetyBridge, INTERBUS-Safety, and PROFIsafe systems.
  • 4Mounts on DIN rail with 24 V supply (I/O) and functional earth ground, simplifying integration into existing systems.
  • 5Meets stringent safety standards with short-circuit and overload protected outputs, ensuring system integrity.
Product Details
IB IL 24 SDI 8-PAC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
48.8 mm
Height
119.8 mm
Depth
71.5 mm
Note on dimensions
Housing dimensions
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Color
yellow
Connection method
Inline data jumper
Transmission speed
500 kbps / 2 Mbps (can be switched)
ID code (dec.)
175
ID code (hex)
AF
Input name
Digital inputs
Number of inputs
4 (for 2-channel assignment) 8 (for 1-channel assignment)
Connection method
Spring-cage connection
Connection technology
2-, 3-, 4-conductor
Input voltage
24 V DC (parameterizable; see technical data.)
Input voltage range "0" signal
-3 V DC ... 5 V DC
Input voltage range "1" signal
11 V DC ... 30 V DC
Typical response time
See technical data
Product type
I/O component
Product family
Inline
Application
IB-Safety
Type
modular
Diagnostics messages
Short-circuit or overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor
Maximum power dissipation for nominal condition
150 W
Transmission medium
Copper
Supply voltage
7.5 V DC (see safety data)
Current draw
max. 230 mA (see safety data)
Supply voltage
24 V DC (see safety data)
Supply voltage
24 V (see safety data)
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)
500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (I/O) / functional ground
500 V AC, 50 Hz, 1 min
Connection name
Inline connector
Connection method
Spring-cage connection
Conductor cross section rigid
0.2 mm² ... 1.5 mm²
Conductor cross section flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Connection method
Spring-cage connection
Conductor cross section, rigid
0.2 mm² ... 1.5 mm²
Conductor cross section, flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
80 hPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
66 hPa ... 108 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Permissible humidity (operation)
10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)
10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice