Product Model

IB IL 24 TC

In Stock
Last updated: 2025/4/24
Phoenix Contact IB IL 24 TC

Selling Points

  • 1High-Performance Digital Input Terminal: The IB IL 24 DI 16-ME supports 16 digital sensors with 2 and 3-wire technology connections.
  • 2Robust Design: Built to withstand temperatures from -25°C to +55°C and humidity levels up to 95%, ensuring reliable operation in harsh environments.
  • 3Diagnostic Indicators: Equipped with diagnostic and status indicators for easy monitoring of terminal performance.
  • 4Efficient Power Management: Consumes a maximum of 4.0 A from the terminal and 60 mA from the local bus, minimizing power consumption.
  • 5Comprehensive Compatibility: Compatible with various Phoenix Contact user manuals and system manuals, ensuring seamless integration into your bus system.
Product Details
IB IL 24 TC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Type
modular
ID code (dec.)
190
ID code (hex)
BE
Length code (hex)
41
Length code (dec)
65
Process data channel
4 bit
Input address area
4 bit
Output address area
0 Byte
Register length
4 bit
Required parameter data
1 Byte
Power consumption
max. 12 W (For R = 12 Ω, L = 1.2 H/48 Ω)
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 60 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 500 mA
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O)
500 V AC, 50 Hz, 1 min
Test voltage: 24 V analog supply (analog I/O)/functional ground
500 V AC, 50 Hz, 1 min
Test voltage: Thermistor / all other areas
1200 V AC, 50 Hz, 1 min
Input name
Resistance sensor
Description of the input
Input for PTC thermistor
Number of inputs
1
Connection method
Spring-cage connection
Connection technology
2-conductor
Sensor types (RTD) that can be used
PTC thermistor according to DIN 44081 or DIN 44082
Input filter time
typ. 10 ms
Nominal value of the current sources
max. 1.2 mA (For non-load voltage of < 8 V DC)
Linear resistance measuring range
2.7 kΩ ... 3.5 kΩ (Shutdown range, total resistance) 50 Ω ... 2.25 kΩ (Operating range, total resistance)
Connection method
Spring-cage connection
Connection technology
2-conductor
Number of outputs
1
Protective circuit
short-circuit and overload proof
Current output signal
500 mA (per output)
Voltage output signal
24 V DC (U
Load/output load voltage output
< 2.7 kΩ (Total resistance for output signal HIGH)
Connection method
Spring-cage connection
Conductor cross section, rigid
0.2 mm² ... 1.5 mm²
Conductor cross section, flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Connection method
Inline data jumper
Transmission speed
500 kbps
Transmission physics
Copper
Width
12.2 mm
Height
119.8 mm
Depth
71.5 mm
Color
green
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
-25 % ... 55 % (75% average, 85% seldom)
Permissible humidity (storage/transport)
-25 % ... 85 %
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice