Product Model
IB IL 400 MLR 1-8A

Selling Points
- 1Advanced Motor Protection: Equipped with electronic motor protection in accordance with IEC 60947-4 for enhanced safety.
- 2Efficient Switching: Enables standard three-phase motors to be switched, protected, and monitored via INTERBUS.
- 3Robust Design: Designed for operation in a wide range of ambient temperatures (-25°C to 55°C) and humidity levels (10% to 85%).
- 4High Current Capacity: Supports up to 20 A of current with external line protection for network supply lines.
- 5Integrated Diagnostics: Provides overcurrent error messages and diagnostic codes for easy troubleshooting and maintenance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 63 mm | Height | 224 mm |
Depth | 109 mm | Number of interfaces | 2 |
Connection method | Inline data jumper | Transmission speed | 500 kbps |
Transmission physics | Copper | ID code (dec.) | 191 |
ID code (hex) | BF | Length code (hex) | 81 |
Length code (dec) | 129 | Process data channel | 8 bit |
Input address area | 1 Byte | Output address area | 1 Byte |
Register length | 1 Byte | Required parameter data | 5 Byte |
Required configuration data | 5 Byte | Number of inputs | 1 |
Number of positions | 4 | Filter time | 0.2 ms |
Product type | I/O component | Product family | Inline |
Type | modular | Mounting position | Panel mounting on horizontal DIN rail |
Operating mode | Process data mode with one byte | Diagnostics messages | Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Module error during self test Message to the master |
Power consumption | max. 4.2 W (entire device) | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 50 mA | Power consumption | max. 0.375 W |
Supply voltage | 24 V DC (via voltage jumper) | Supply voltage range | 19.2 V DC ... 28.8 V DC (including all tolerances, including ripple) |
Current draw | max. 160 mA | Test voltage: Supply voltage U | 1.2 kV AC, 50 Hz, 1 min |
Test voltage: Supply voltage U | 1.2 kV AC, 50 Hz, 1 min | Test voltage: Supply voltage U | 1.2 kV AC, 50 Hz, 1 min |
Test voltage: Supply voltage U | 1.2 kV AC, 50 Hz, 1 min | Test voltage: Local bus/400 V level | 1.2 kV AC, 50 Hz, 1 min |
Test voltage: Local bus/Brake control switch | 1.2 kV AC, 50 Hz, 1 min | Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 55 °C | Note | Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector |
Air pressure (operation) | 80 kPa ... 106 kPa (up to 2000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 85 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 85 % (non-condensing) | Protection class | I (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting | Assembly note | To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below. |
Mounting position | Panel mounting on horizontal DIN rail |
Specifications may be subject to change without notice