Product Model
IB IL AI 2/SF-230-PAC

Selling Points
- 1High Accuracy Measurement: Achieve precise measurements with a resolution of 16 bits.
- 2Rapid Acquisition: Quickly acquire measurement values with an A/D conversion time of 120 µs per channel.
- 3Excellent Noise Suppression: Minimize noise interference with common mode rejection of up to 110 dB.
- 4Multi-Wire Connection: Easily connect sensors using 2 and 3-wire technology.
- 5Durable Design: Withstand various environmental conditions, including shock tests and ESD protection.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 12.2 mm | Height | 136.8 mm |
Depth | 71.5 mm | Note on dimensions | Housing dimensions |
Note on application | Only for industrial use | Number of interfaces | 2 |
Connection method | Inline data jumper | Transmission speed | 500 kbps |
ID code (dec.) | 127 | ID code (hex) | 7F |
Length code (hex) | 02 | Length code (dec) | 02 |
Process data channel | 32 bit | Input address area | 4 Byte |
Output address area | 4 Byte | Register length | 32 bit |
Required parameter data | 6 Byte | Required configuration data | 4 Byte |
Input name | Analog inputs | Description of the input | Single-ended inputs, voltage or current |
Number of inputs | 2 | A/D conversion time | typ. 120 µs (per channel) |
Connection method | Inline shield connector | Connection technology | 2-conductor |
Note regarding the connection technology | shielded | Current input signal | 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA |
Input resistance current input | 50 Ω (Shunt) | Voltage input signal | 0 V ... 10 V
-10 V ... 10 V |
Input resistance of voltage input | > 220 kΩ | Data formats | IB IL, IB ST, IB RT, standardized representation |
Limit frequency (3 dB) | 230 Hz | Common mode voltage range signal - ground | 40 V (Between current input and functional ground)
40 V (between voltage input and functional ground) |
Measuring principle | Successive approximation | Measured value resolution | 16 bits (15 bits + sign bit) |
Measured value representation | 16 bit two's complement | Protective circuit | Surge protection; Suppressor diodes in the analog inputs |
Product type | I/O component | Product family | Inline |
Type | modular | Scope of delivery | including Inline connector and labeling field |
Operating mode | Process data operation with 2 words | Special properties | 3 dB base frequency at 230 Hz |
Diagnostics messages | Failure of the internal I/O supply yes
I/O error Error message in the process data
User error Error message in the process data | Article revision | 04 |
Overvoltage category | II (IEC 60664-1, EN 60664-1) | Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Maximum power dissipation for nominal condition | 0.9 W | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 60 mA
typ. 45 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 18 mA
typ. 13 mA |
Test voltage: 7.5 V supply (bus logic), 24 V supply U | 500 V AC, 50 Hz, 1 min | Test voltage: 7.5 V supply (bus logic), 24 V supply U | 500 V AC, 50 Hz, 1 min |
Test voltage: I/O/functional ground | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice