  • 1High-Speed Data Transfer: Transmits data at 500 kbps in the local bus.
  • 2Versatile Signal Input: Connects either voltage or current signals with ranges from 0 to 20 mA and 0 to 10 V.
  • 3Independent Channel Parameterization: Channels can be parameterized independently via the bus system.
  • 4Fast Process Data Update: Updates process data for both channels within a maximum of 1.5 ms.
  • 5Robust Design: Features IP20 degree of protection and includes inline connectors and marking fields.
Product Details
IB IL AI 2/SF-PAC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
12.2 mm
Height
136.8 mm
Depth
71.5 mm
Note on dimensions
Housing dimensions
Note on application
Only for industrial use
CCCex note
Use in potentially explosive areas is not permitted in China.
Number of interfaces
2
Connection method
Inline data jumper
Transmission speed
500 kbps
ID code (dec.)
127
ID code (hex)
7F
Length code (hex)
02
Length code (dec)
02
Process data channel
32 bit
Input address area
4 Byte
Output address area
4 Byte
Register length
32 bit
Required parameter data
6 Byte
Required configuration data
4 Byte
Input name
Analog inputs
Description of the input
Single-ended inputs, voltage or current
Number of inputs
2
A/D conversion time
typ. 120 µs (per channel)
Connection method
Inline shield connector
Connection technology
2-conductor
Note regarding the connection technology
shielded
Current input signal
0 mA ... 20 mA 4 mA ... 20 mA -20 mA ... 20 mA
Input resistance current input
50 Ω (Shunt)
Voltage input signal
0 V ... 10 V -10 V ... 10 V
Input resistance of voltage input
> 220 kΩ
Data formats
IB IL, IB ST, IB RT, standardized representation
Limit frequency (3 dB)
40 Hz
Common mode voltage range signal - ground
40 V (Between current input and functional ground) 40 V (between voltage input and functional ground)
Measuring principle
Successive approximation
Measured value resolution
16 bits (15 bits + sign bit)
Measured value representation
16 bit two's complement
Protective circuit
Surge protection; Suppressor diodes in the analog inputs
Product type
I/O component
Product family
Inline
Type
modular
Scope of delivery
including Inline connector and labeling field
Operating mode
Process data operation with 2 words
Diagnostics messages
Failure of the internal I/O supply yes I/O error Error message in the process data User error Error message in the process data
Article revision
12
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
0.9 W
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 60 mA typ. 45 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 18 mA typ. 13 mA
Test voltage: 7.5 V supply (bus logic), 24 V supply U
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logic), 24 V supply U
500 V AC, 50 Hz, 1 min
Test voltage: I/O/functional ground
500 V AC, 50 Hz, 1 min
Connection name
Inline connector
Connection method
Spring-cage connection
Conductor cross section rigid
0.08 mm² ... 1.5 mm²
Conductor cross section flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
10 % ... 95 % (non-condensing)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice