Product Model
IB IL SGI 2/F-2MBD-PAC

Selling Points
- 1Fast Inputs for Strain Gauges: Equipped with 2 quick inputs for strain gauges.
- 26- and 4-Wire Connection: Supports both 6- and 4-wire connection methods for strain gauges.
- 3Sensor Supply Voltage: Provides sensor supply voltage, eliminating the need for an external power supply.
- 4Process Data Operation: Communicates via process data or parameter channel (PCP) for efficient data transfer.
- 5Diagnostic Indicators: Features diagnostic and status indicators for easy monitoring and troubleshooting.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 48.8 mm | Height | 136 mm |
Depth | 71.5 mm | Note on application | Only for industrial use |
Number of interfaces | 2 | Connection method | Inline data jumper |
Transmission speed | 2 Mbps | Transmission physics | Copper |
ID code (dec.) | 223 | ID code (hex) | DF |
Length code (hex) | 03 | Length code (dec) | 03 |
Process data channel | 48 bit | Input address area | 6 Byte |
Output address area | 6 Byte | Register length | 32 bit |
Required parameter data | 15 Byte | Required configuration data | 5 Byte |
Description of the input | Input channels for strain gauge | Number of inputs | 2 |
Connection technology | 6 or 4-wire, twisted pair shielded cable | Bridge difference U | Measuring range specified by selecting the characteristic and the bridge voltage |
Bridge voltage U | 3.3 V
5 V | Measured value representation | 15 bit + sign bit |
Characteristics | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±4 mV/V
+1 mV/V, +2 mV/V, +3 mV/V, +4 mV/V | Output description | Voltage output |
Number of outputs | 2 | Impedance | > 58.3 Ω (typical; permissible total resistance of the strain gauge) |
Output voltage | 5 V
3.3 V | Output current | typ. 55 mA (with U
typ. 85 mA (with U |
Product type | I/O component | Product family | Inline |
Type | modular | Scope of delivery | including Inline connectors and marking fields |
Operating mode | Process data operation with 3 words, PCP with 1 word | Special properties | 2 fast inputs
4-, 6-conductor connection technology |
Diagnostics messages | Failure of the power supply at U
Failure of or insufficient communications power U
I/O error Error message in the process data | Article revision | 07 |
Maximum power dissipation for nominal condition | 1.25 W | Supply voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 110 mA
typ. 100 mA | Supply voltage | 24 V DC (via voltage jumper) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | typ. 32 mA (with maximum load of 58.3 Ω when U
typ. 8 mA (without strain gauge) |
Test voltage: Logic/analog I/O (digital isolator) | 500 V AC, 50 Hz, 1 min | Test voltage: Functional ground/analog I/O (isolating distance) | 500 V AC, 50 Hz, 1 min |
Test voltage: Logic/functional ground (isolating distance) | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice