  • 1High-Precision Inputs: 2 precise and fast inputs for strain gauge measurements.
  • 24-6 Conductor Connection: Supports both 4- and 6-conductor connection technology.
  • 3IP20 Protection: Designed for control cabinets with IP20 degree of protection.
  • 4Advanced Diagnostics: Includes diagnostics messages for power supply failure and communication errors.
  • 5Flexible Configuration: Parameterizable process data update from 200 µs to 100 ms.
Product Details
IB IL SGI 2/P
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Type
modular
Operating mode
Process data operation with 3 words, PCP with 1 word
ID code (dec.)
223
ID code (hex)
DF
Length code (hex)
03
Length code (dec)
03
Process data channel
48 bit
Input address area
48 bit
Output address area
48 bit
Register length
32 bit
Required parameter data
23 Byte
Required configuration data
5 Byte
Power consumption
typ. 1.2 W (Device in nominal operation) max. 3.2 W (Device with maximum load)
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 100 mA typ. 85 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 100 mA typ. 25 mA (in case of typical load of 350 Ohm per channel) 80 mA (for a maximum load of 55 Ω and display) 7 mA (for no-load operation without strain gauge or display)
Test voltage: Logic/analog I/O (digital isolator)
500 V AC, 50 Hz, 1 min
Test voltage: RS-485/analog I/O (isolating distance)
500 V AC, 50 Hz, 1 min
Test voltage: N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Functional ground/analog I/O (isolating distance)
500 V AC, 50 Hz, 1 min
Test voltage: Logic/RS-485 (digital isolator)
500 V AC, 50 Hz, 1 min
Test voltage: N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Functional ground/RS-485 (isolating distance)
500 V AC, 50 Hz, 1 min
Test voltage: Logic / N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Functional ground/N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Logic / N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Functional ground/N/O contact K
500 V AC, 50 Hz, 1 min
Test voltage: Logic/functional ground (isolating distance)
500 V AC, 50 Hz, 1 min
Description of the input
Input channels for strain gauge
Number of inputs
2
Connection technology
6 or 4-wire, twisted pair shielded cable
Bridge difference U
Measuring range specified by selecting the characteristic
Bridge voltage U
5 V
Measured value representation
15 bit + sign bit
Process data update
typ. 100 ms (12.5 ms, depends on the configuration)
Characteristics
±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V
Description
Floating N/O contact
Quantity
2 (K
Contact resistance
< 1 Ω (typical) 5 Ω (maximum)
Typical response time
100 ms (typical)
Protective circuit
Short-circuit protection of the voltage outputs; Yes, at least 1 minute through temperature monitoring
Output description
Voltage output
Number of outputs
2
Impedance
> 55 Ω (minimum)
Output voltage
typ. 5 V
Output current
max. 90 mA (with U
Maximum output current
max. 90 mA (with U
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection method
Inline data jumper
Transmission speed
500 kbps
Transmission physics
Copper
Designation
V.24 (RS-485) serial interface
Network
Yes
Addressing
Address 1 = Measured gross/net value Address 2 = Measured tare value
Termination resistor
120 Ω
Transmission protocol
STX/ETX
Width
48.8 mm
Height
136 mm
Depth
71.5 mm
Color
green
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice