Product Model

IB IL TEMP 4/8 RTD

In Stock
Last updated: 2025/4/18
Phoenix Contact IB IL TEMP 4/8 RTD

Selling Points

  • 1High Precision Temperature Measurement: The module supports platinum and nickel sensors, ensuring high precision in temperature measurement.
  • 28-Channel Input Module: Equipped with 8 analog inputs for resistive temperature detectors, ideal for multi-point temperature monitoring.
  • 3DIN Rail Mounting: Conveniently mounts on DIN rail, making it easy to integrate into industrial control systems.
  • 4Wide Operating Temperature Range: Operates between -25°C to +55°C, suitable for various industrial environments.
  • 5Compact Design: Dimensions of 136.8 x 48.8 x 71.5 mm, providing a compact solution for space-constrained applications.
Product Details
IB IL TEMP 4/8 RTD
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Type
modular Inline
Operating mode
Process data mode with 5 words/1 word PCP
ID code (dec.)
223
ID code (hex)
DF
Length code (hex)
05
Length code (dec)
05
Process data channel
80 bit
Input address area
10 Byte
Output address area
10 Byte
Register length
96 bit
Required parameter data
31 Byte
Power consumption
typ. 1.24 W
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
typ. 75 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
typ. 28 mA
Test voltage: 7.5 V supply (bus logic)/±15.5 V, ±5 V analog supply (analog I/O)
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V supply (bus logic)/functional ground
500 V AC, 50 Hz, 1 min
Test voltage: ±15.5 V, ±5 V analog supply (analog I/O)/functional ground
500 V AC, 50 Hz, 1 min
Input name
Analog RTD inputs
Description of the input
2 x 4 channels multiplex, 8 PCP channels or 4 channels without multiplex
Number of inputs
8 (for resistance temperature detectors)
Connection method
Spring-cage connection
Connection technology
2, 3-conductor
A/D conversion time
max. 10 µs
Sensor types (RTD) that can be used
Pt, Ni, KTY, Cu sensors, linear resistors
Data formats
IB IL, IB ST, S7 compatible
Measuring principle
Successive approximation
Measured value representation
16 bits (15 bits + sign bit)
Linear resistance measuring range
0 Ω ... 400 Ω 0 Ω ... 20 kΩ
Process data update
6 ms (Up to 230 ms possible depending on operating mode)
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection method
Inline data jumper
Transmission speed
500 kbps
Transmission physics
Copper
Width
48.8 mm
Height
119.8 mm
Depth
71.5 mm
Color
green
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice