Product Model
IB IL UTH 4/L-ECO

Selling Points
- 1Supports type L thermocouples according to DIN EN 43710.
- 24 differential inputs for thermocouples with 2-wire connection technology.
- 3Measuring range: -200°C to +900°C.
- 4Diagnostic information in the process data word for enhanced monitoring.
- 5Compact design with dimensions: 12.2 mm x 119.8 mm x 71.5 mm and IP20 protection.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 12.2 mm | Height | 119.8 mm |
Depth | 71.5 mm | Color | green |
No. of channels | 2 | Connection method | Inline data jumper |
Transmission speed | 500 kbps | ID code (dec.) | 126 |
ID code (hex) | 7E | Length code (hex) | 04 |
Length code (dec) | 04 | Process data channel | 64 bit |
Input address area | 8 Byte | Output address area | 0 Byte |
Register length | 64 bit | Required parameter data | 1 Byte |
Required configuration data | 4 Byte | Input name | Analog UTH inputs |
Description of the input | Differential inputs | Number of inputs | 4 (Type L) |
Connection method | Inline connector | Connection technology | 2-conductor |
Note regarding the connection technology | shielded | A/D conversion time | typ. 120 ms |
A/D converter resolution | 24 bit | Sensor types that can be used (TC) | L |
Measuring principle | Sigma/Delta process | Measured value representation | 16 bits (15 bits + sign bit) |
Process data update | < 10 ms | Protective circuit | Transient protection of inputs |
Product type | I/O component | Product family | Inline ECO |
Type | modular | Scope of delivery | including Inline connector |
Diagnostics messages | Failure of the internal I/O supply I/O error message sent to the bus coupler
Checksum error I/O error message sent to the bus coupler | Article revision | 02 |
Supply voltage | 7.5 V DC (via voltage jumper) | Current draw | max. 55 mA
typ. 38 mA |
Supply voltage | 24 V DC (via voltage jumper) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 39 mA
typ. 32 mA | Test voltage: Bus logic (local bus, communications power) | 500 V AC, 50 Hz, 1 min |
Test voltage: Analog I/O | 500 V AC, 50 Hz, 1 min | Test voltage: Functional ground | 500 V AC, 50 Hz, 1 min |
Connection name | Inline connector | Connection method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Connection method | Spring-cage connection | Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Ambient temperature (operation) | 0 °C ... 55 °C |
Degree of protection | IP20 | Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) | Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) | Mounting type | DIN rail mounting |
Specifications may be subject to change without notice