Product Model

IBS IL 24 BK-T/U-XC-PAC

In Stock
Last updated: 2025/4/18
Phoenix Contact IBS IL 24 BK-T/U-XC-PAC

Selling Points

  • 1Connects Inline stations to INTERBUS remote buses efficiently.
  • 2Operates in temperatures from -40 °C to +70 °C, making it suitable for harsh environments.
  • 3Ensures safe operation with electrical isolation, reducing the risk of electrical shock.
  • 4Provides 5 V, 7.5 V, and 24 V DC supply voltages for connected devices.
  • 5Built with coated PCBs and IP20 protection, ensuring long-lasting performance in various conditions.
Product Details
IBS IL 24 BK-T/U-XC-PAC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
48.8 mm
Height
135 mm
Depth
71.5 mm
Note on application
Only for industrial use
Number of interfaces
2 (Connected to functional ground with a capacitor)
Connection method
Inline shield connector
Transmission speed
500 kbps
Transmission physics
Copper
Number of interfaces
1
Connection method
Inline data jumper
Transmission speed
500 kbps
Number of supported devices
max. 63
Number of local bus devices that can be connected
max. 63
Number of devices with parameter channel
62
Number of supported branch terminals with remote bus branch
max. 15
ID code (dec.)
04
ID code (hex)
04
Length code (hex)
00
Input address area
0 Byte
Output address area
0 Byte
Register length
0 bit
Product type
I/O component
Product family
Inline
Type
modular
Scope of delivery
including Inline connectors and marking fields
Special properties
Extreme conditions version
Article revision
02
Maximum power dissipation for nominal condition
30 W
Protective circuit
Reverse polarity protection
Supply voltage
24 V DC (via Inline connector)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 1.25 A (with max. number of connected I/O terminal blocks) typ. 100 mA (without connected Inline I/O terminals)
Supply voltage
7.5 V DC ±5 %
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Test voltage: 5 V supply, incoming remote bus / 5 V supply outgoing remote bus
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply incoming remote bus / 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply, incoming remote bus / 24 V main supply, 24 V segment supply
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply incoming remote bus / functional ground
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply outgoing remote bus / I/O (U
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply outgoing remote bus / communications power (U
500 V AC, 50 Hz, 1 min
Test voltage: 5 V supply outgoing remote bus / functional ground
500 V AC, 50 Hz, 1 min
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply/functional ground
500 V AC, 50 Hz, 1 min
Test voltage: Communications power (U
500 V AC, 50 Hz, 1 min
Test voltage: 24 V main supply, 24 V segment supply/functional ground
500 V AC, 50 Hz, 1 min
Connection name
Inline connector
Connection method
Spring-cage connection
Conductor cross section rigid
0.08 mm² ... 1.5 mm²
Conductor cross section flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Ambient temperature (operation)
-25 °C ... 55 °C -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protection
IP20
Air pressure (operation)
80 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice