Product Model
IBS IL 24 RB-T-2MBD-PAC

Selling Points
- 12 Mbps transmission speed for efficient data transfer.
- 2Ensures reliable operation in control cabinets with IP20 protection.
- 3Supports remote bus branches for extended network connectivity.
- 4Compatible with 24 V DC supply voltage for seamless integration.
- 5Compact dimensions (12.2 mm x 135 mm x 71.5 mm) for easy installation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 12.2 mm | Height | 135 mm |
Depth | 71.5 mm | Note on application | Only for industrial use |
Connection method | Inline data jumper | Transmission speed | 2 Mbps |
Connection method | Inline shield connector | Transmission speed | 2 Mbps |
Transmission physics | RS-485 | Connection method | Inline data jumper |
Transmission speed | 2 Mbps | Transmission physics | Copper |
Number of local bus devices that can be connected | max. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.) | ID code (dec.) | 04 |
ID code (hex) | 04 | Length code (hex) | 0 |
Length code (dec) | 0 | Process data channel | 0 bit |
Input address area | 0 Byte | Output address area | 0 Byte |
Register length | 0 bit | Required parameter data | 0 Byte |
Required configuration data | 0 Byte | Product type | I/O component |
Product family | Inline | Type | modular |
Scope of delivery | including Inline connector and labeling field | Special properties | with remote bus branch |
Article revision | 07 | Maximum power dissipation for nominal condition | 0.7 W |
Supply voltage | 24 V DC (via voltage jumper) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | typ. 29 mA | Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus | 500 V AC, 50 Hz, 1 min |
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min |
Test voltage: 5 V supply incoming remote bus / functional ground | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus | 500 V AC, 50 Hz, 1 min |
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min |
Test voltage: 5 V supply outgoing remote bus, electrically isolated from functional ground | 500 V AC, 50 Hz, 1 min | Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus | 500 V AC, 50 Hz, 1 min | Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min |
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus terminal module supply, 5 V communications power, bus branch terminal electrically isolated from functional ground | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus | 500 V AC, 50 Hz, 1 min |
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min |
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from the functional ground | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 55 °C | Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | DIN rail mounting |
Specifications may be subject to change without notice