Product Model
IBS IP 400 ME-ELR 1-3A DI4

Selling Points
- 1Easy installation with pluggable connections.
- 2Robust design with IP54 protection.
- 3Advanced motor monitoring via INTERBUS.
- 4High power networking: 400 V AC / 20 A.
- 5Compact dimensions: 355 mm x 180 mm x 100 mm.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Type | Stand-Alone | Type | Electronic motor starter |
Connection method | POWER-COMBICON | Designation | Terminal strip X13 and X15 |
Number of positions | 2 | Pg screw connection | Pg16R |
Supply voltage | 24 V DC (U | Supply voltage range | 20 V DC ... 30 V DC (including ripple) |
Supply current | typ. 0.17 A (at U | Ripple | Permissible ripple 3.6 V |
Max. current carrying capacity | 16 A | Derating | from 30 °C 0.1A/K |
Number of inputs | 4 | Connection method | M12 connector (A-coded) |
Connection technology | Sockets X33 to X36 | Number of positions | 5 |
Input voltage | 24 V DC (U | Input voltage range "0" signal | -30 V ... 5 V (binary "0") |
Input voltage range "1" signal | 13 V ... 30 V (binary "1") | Filter time | 3 ms |
Typical input current per channel | approx. 5 mA (for U | Connection method | M12 connector, B-coded |
Designation connection point | M12 connector; X30 (IN) and X31 (OUT) | Number of positions | 5 |
Permissible conductor cross section | 0.25 mm² ... 0.75 mm² (flexible) | Width | 355 mm |
Height | 180 mm | Depth | 100 mm |
Drill hole spacing | 386 mm | Note on dimensions | Module electronics without lower part |
Drill hole spacing | 386 mm | Degree of protection | IP54 |
Ambient temperature (operation) | -20 °C ... 55 °C (non-condensing) | Note | Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Notes on operation Permitted network type TN network, TT network, IT network available on request |
Air pressure (operation) | 86 kPa ... 106 kPa (up to 2000 m above sea level) | Air pressure (storage/transport) | 86 kPa ... 106 kPa (up to 2000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 75 °C | Permissible humidity (operation) | 4 % ... 100 % (non-condensing) |
Permissible humidity (storage/transport) | 75 % (slight temporary condensation may sometimes appear on the housing) | Protection class | I (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | Wall mounting |
Specifications may be subject to change without notice