Product Model

IBS IP 400 ME-ELR 2-3A DI4

In Stock
Last updated: 2025/4/18
Phoenix Contact IBS IP 400 ME-ELR 2-3A DI4

Selling Points

  • 1Switches three-phase standard motors via INTERBUS.
  • 2Available in IP54 and IP67 housing variants for various industrial environments.
  • 3Features pluggable connections and removable module electronics.
  • 4Includes status and diagnostics displays on the module.
  • 5Supports variable frequency drives and initiator inputs for sensor connections.
Product Details
IBS IP 400 ME-ELR 2-3A DI4
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Type
Stand-Alone
Type
Electronic motor starter
Diagnostics messages
Mains failure, phase failure Error message in the diagnostic code (bus) and display via the LED ERR on the module Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in the diagnostic code (bus) and display via the LED ERR on the module Sensor supply failure Error message in the diagnostic code (bus) and display via the LED ERR on the module Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module Short-circuit or overload of the digital outputs Message in the diagnostic code Module error during self test Message to the master
Connection method
POWER-COMBICON
Designation
Terminal strip X13 and X15
Number of positions
2
Permissible conductor cross section
1.5 mm² ... 4 mm²
Pg screw connection
Pg16R
Supply voltage
24 V DC (U
Supply voltage range
20 V DC ... 30 V DC (including ripple)
Supply current
0.17 A (at U
Ripple
Permissible ripple 3.6 V
Max. current carrying capacity
16 A
Derating
from 30 °C 0.1A/K
Test voltage: Incoming/outgoing remote bus
350 V AC, 50 Hz, 1 min
Test voltage: Remote bus / supply voltage U
350 V AC, 50 Hz, 1 min
Number of inputs
4
Connection method
M12 connector
Connection technology
3-, 4-conductor
Number of positions
5
Input voltage
24 V DC (U
Input voltage range "0" signal
-30 V ... 5 V (binary "0")
Input voltage range "1" signal
13 V ... 30 V (binary "1")
Filter time
3 ms
Typical input current per channel
approx. 5 mA (for U
Connection method
MINI COMBICON
Designation connection point
X30 (IN) and X31 (OUT)
Number of positions
10
Permissible conductor cross section
max. 1.5 mm²
Diagnostics
Mains failure, phase failure
Message
Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited
Message
Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics
Sensor supply failure
Message
Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics
Overcurrent
Message
Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics
Output stage cannot be controlled
Message
Error message in the diagnostic code (bus) and display via the LED ERR on the module
Diagnostics
Short-circuit or overload of the digital outputs
Message
Message in the diagnostic code
Diagnostics
Module error during self test
Message
Message to the master
Width
355 mm
Height
180 mm
Depth
100 mm
Drill hole spacing
386 mm
Note on dimensions
Module electronics without lower part
Drill hole spacing
386 mm
Degree of protection
IP54
Ambient temperature (operation)
-20 °C ... 55 °C (non-condensing)
Note
Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector Notes on operation Permitted network type TN network, TT network, IT network available on request
Air pressure (operation)
86 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
86 kPa ... 106 kPa (up to 2000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 75 °C
Permissible humidity (operation)
4 % ... 100 % (non-condensing)
Permissible humidity (storage/transport)
75 % (slight temporary condensation may sometimes appear on the housing)
Protection class
I (IEC 61140, EN 61140, VDE 0140-1)
Noise emission
Test of emitted interference, housing, in acc. with EN 50081-2:1993 EN 55011:1991 class A
Air clearances and creepage distances
in accordance with EN 50178: 1998
Mounting type
Wall mounting

Specifications may be subject to change without notice