Product Model

IBS RL 400 MLR R DIO6/1 LK

In Stock
Last updated: 2025/4/18
Phoenix Contact IBS RL 400 MLR R DIO6/1 LK

Selling Points

  • 1Utilizes 500 kbaud fiber optic technology for high-speed communication.
  • 2Includes an integrated motor protection relay for 220 V AC to 440 V AC, up to 8 A.
  • 3Equipped with a rugged metal housing offering IP67 protection against dust and water.
  • 4Features comprehensive diagnostic functions including motor current monitoring and error message display.
  • 5Offers multiple input and output connections via M12 connectors and POWER-COMBICON terminal strips.
Product Details
IBS RL 400 MLR R DIO6/1 LK
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
185.1 mm
Height
193 mm
Depth
138 mm
Connection method
Fiber optics
Transmission speed
500 kbps
ID code (dec.)
3
ID code (hex)
03
Length code (hex)
01
Length code (dec)
1
Process data channel
16 bit
Input address area
2 Byte
Output address area
2 Byte
Register length
2 Byte
Number of inputs
6
Connection method
M12 connector
Connection technology
3-, 4-conductor
Number of positions
5
Input voltage
24 V DC (DIN EN 61131-2)
Input voltage range "0" signal
0 V ... 5 V
Input voltage range "1" signal
11 V ... 30 V
Filter time
3 ms
Typical input current per channel
5 mA (for U
Product type
I/O component
Product family
Ruggedline
Type
Block design
Diagnostics messages
Mains failure, phase failure, blown fuse Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Sensor supply failure Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Failure of the actuator supply Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Motor overcurrent Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Output stage cannot be controlled Error message in diagnostic code (bus) and display by means of the E LED on the motor starter Module error during self test Message to the master
Supply voltage
24 V DC
Supply voltage range
18.5 V DC ... 32 V DC (including ripple)
Ripple
3.6 V
Connection method
M12 connector
Degree of protection
IP65/IP67
Ambient temperature (operation)
0 °C ... 55 °C
Air pressure (operation)
860 hPa ... 1080 hPa (up to 1500 m above sea level)
Air pressure (storage/transport)
660 hPa ... 1080 hPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Permissible humidity (operation)
100 %
Permissible humidity (storage/transport)
95 % (non-condensing)
Protection class
I (IEC 61140, EN 61140, VDE 0140-1)
Air clearances and creepage distances
in accordance with EN 50178: 1998
Mounting type
on mounting panel Wall mounting