Product Model
ILB ETH 24 DI16 DIO16-2TX

Selling Points
- 1Supports 10/100 Mbps with auto negotiation.
- 2IP20 degree of protection and robust ambient temperature range (-25 °C to 60 °C).
- 316 fixed and 16 freely selectable digital inputs.
- 416 outputs with short-circuit and overload protection.
- 5Spring-cage connection method for quick and secure setup.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 156 mm | Height | 141 mm |
Depth | 57 mm | Note on dimensions | Specfications with connectors |
CCCex note | Use in potentially explosive areas is not permitted in China. | No. of channels | 2 |
Connection method | RJ45 jack | Transmission speed | 10/100 Mbps (with auto negotiation) |
Transmission physics | Copper | Input name | Digital inputs |
Description of the input | 16 fixed and 16 freely selectable | Number of inputs | 32 |
Connection method | Spring-cage connection | Connection technology | 3-conductor |
Nominal input voltage U | 24 V DC | Nominal input current at U | typ. 5 mA |
Typical response time | approx. 500 µs | Delay at signal change from 0 to 1 | 500 µs |
Protective circuit | Short-circuit protection, overload protection of the sensor supply | Output name | Digital outputs |
Connection method | Spring-cage connection | Connection technology | 2-conductor |
Number of outputs | 16 | Protective circuit | Short-circuit and overload protection |
Maximum output current per channel | 500 mA | Nominal output voltage | 24 V DC |
Product type | I/O component | Product family | Inline |
Type | Block design | Scope of delivery | including Inline connector |
No. of channels | 32 | Diagnostics messages | Short-circuit or overload of the digital outputs Message in the diagnostics register
Short-circuit, sensor supply Message in the diagnostics register
Undervoltage Power supply for sensors Message in the diagnostics register |
Supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | 70 mA | Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | 4 A |
Supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | 4 A | Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | 4 A |
Supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | 4 A | Current draw | 70 mA |
Test voltage: I/O / Logic | 500 V AC, 50 Hz, 1 min | Test voltage: I/O area / FE | 500 V AC, 50 Hz, 1 min |
Test voltage: Logic / FE | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm | Connection method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
Ambient temperature (operation) | -25 °C ... 60 °C | Degree of protection | IP20 |
Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) | Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | max. 85 % (non-condensing) |
Noise emission | Industrial environment | Mounting type | NS 35/7,5
DIN rail mounting |