Product Model

ILB IB 24 DI32

In Stock
Last updated: 2025/4/20
Phoenix Contact ILB IB 24 DI32

Selling Points

  • 1High-Reliability Design: Built with robust components for long-lasting performance in harsh industrial environments.
  • 232 Digital Inputs: Supports up to 32 digital inputs for comprehensive data collection and processing.
  • 324 V DC Power Supply: Operates on a stable 24 V DC power supply, ensuring consistent performance.
  • 4Wide Operating Temperature Range: Functions between -25 °C and 60 °C, suitable for various industrial settings.
  • 5IP20 Protection Class: Ensures protection against solid particles and water spray, meeting industrial standards.
Product Details
ILB IB 24 DI32
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
156 mm
Height
141 mm
Depth
57 mm
Note on dimensions
Specfications with connectors
Color
green
Connection method
Inline shield connector
Transmission speed
500 kbps
Input name
Digital inputs
Description of the input
EN 61131-2 type 1
Number of inputs
32
Connection method
Spring-cage connection
Connection technology
3-conductor
Input voltage
24 V DC
Input voltage range "0" signal
-30 V DC ... 5 V DC
Input voltage range "1" signal
15 V DC ... 30 V DC
Nominal input voltage U
24 V DC
Nominal input current at U
5 mA
Total sensor current
max. 4 A
Typical response time
approx. 500 µs
Protective circuit
Short-circuit protection, overload protection of the sensor supply
Product type
I/O component
Product family
Inline
Type
Block design
Scope of delivery
including Inline connector
No. of channels
32
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
60 mA
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
2 A
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
2 A
Current draw
60 mA
Test voltage: I/Os / incoming remote bus
500 V AC, 50 Hz, 1 min
Test voltage: I/Os / outgoing remote bus
500 V AC, 50 Hz, 1 min
Test voltage: I/O area / FE
500 V AC, 50 Hz, 1 min
Test voltage: Incoming remote bus / FE
500 V AC, 50 Hz, 1 min
Test voltage: Outgoing remote bus / FE
500 V AC, 50 Hz, 1 min
Test voltage: Incoming remote bus / outgoing remote bus
500 V AC, 50 Hz, 1 min
Connection name
Inline connector
Connection method
Spring-cage connection
Conductor cross section rigid
0.08 mm² ... 1.5 mm²
Conductor cross section flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
8 mm
Ambient temperature (operation)
-25 °C ... 60 °C
Degree of protection
IP20
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
max. 85 % (non-condensing)
Permissible humidity (storage/transport)
95 % (non-condensing)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Noise emission
Class B (residential)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice