Phoenix Contact ILC 171 ETH 2TX

Selling Points

  • 1Supports PROFINET and Modbus/TCP for versatile communication protocols.
  • 2Free engineering with PC Worx Express for easy programming (IEC 61131-3).
  • 3Program memory and mass storage (512 kB/512 kB) for efficient data handling.
  • 4Integrated web server with HTML 5 for real-time visualization using WebVisit/atvise®.
  • 5Complete INTERBUS master with 4096 I/O points for comprehensive control systems.
Product Details
ILC 171 ETH 2TX
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note on application
Only for industrial use
CCCex note
Use in potentially explosive areas is not permitted in China.
Product type
Controller
Product family
Inline-Controller
Type
modular
Article revision
12
Diagnostics display
no
Processor
AlteraNios® II 64 MHz
Clock frequency
64 MHz
Retentive data storage
48 kByte (NVRAM)
Program memory
512 kByte
Data storage system
512 kByte
Number of control tasks
8
Amount of process data
max. 4096 bit (INTERBUS)
Number of supported devices
max. 128
Number of local bus devices that can be connected
max. 63 (observe current consumption)
Number of devices with parameter channel
max. 24
Number of supported branch terminals with remote bus branch
max. 3
Amount of process data
max. 32768 bit (internal Modbus /TCP client)
Number of Modbus/TCP clients
max. 16 later than FW 4.42
Device function
PROFINET device
Specification
2.2
Device ID
007A
Vendor ID
00B0
Diagnostics display
no
Controller redundancy
no
Safety function
no
Programming languages supported
Instruction list (IL) Symbolic flowchart (SFC) Ladder diagram (LD) Function block diagram (FBD) Structured text (ST)
Engineering tool
PC Worx PC Worx Express
Configuration tool
Config+ Version 1.01 or later
Diagnostics tool
DIAG+
Runtime system
eCLR
Application interface
OPC
Transmission medium
Copper
Realtime clock
yes
Description realtime clock
integrated (rechargeable battery buffered)
Supply voltage
24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply voltage range
19.2 V DC ... 30 V DC
Current draw
80 mA (without connected I/O terminal blocks)
Supply voltage
7.5 V DC ±5 %
Supply voltage
24 V DC -15 % / +20 %
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Supply voltage
24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 8 A DC 6 mA (without sensors)
Supply voltage
24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 8 A DC 10 mA (without actuators)
Input name
Digital inputs
Description of the input
EN 61131-2 type 1 NPN/PNP
Number of inputs
8
Cable length
max. 30 m
Connection method
Inline potential distributor
Connection technology
2-, 3-, 4-conductor
Input voltage range
-0.5 V ... 30 V
Input voltage range "0" signal
-0.5 V ... 5 V
Input voltage range "1" signal
15 V ... 30 V
Nominal input current at U
typ. 7 mA max. 15 mA
Input filter time
typ. 5 ms (Signal change 01) typ. 5 ms ()
Output name
Digital outputs
Connection method
Spring-cage connection
Connection technology
2-, 3-, 4-conductor
Number of outputs
4
Maximum output current per channel
500 mA
Maximum output current per module / terminal block
2 A
Nominal load, lamp
12 W
Nominal load, ohmic
12 W
Behavior with inductive overload
Output can be destroyed
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Web server
yes
Bus system
RJ45
Number of interfaces
2
Connection method
RJ45 jack
Transmission speed
10/100 Mbps
No. of channels
2
Number of interfaces
1
Connection method
Inline data jumper
Transmission speed
500 kBaud / 2 MBaud (can be switched)
Bus system
RS-232
Number of interfaces
1
Connection method
6-pos. MINI DIN socket (PS/2)
Transmission speed
max. 115.2 kbps
Transmission physics
Copper
No. of channels
1
Width
80 mm
Height
119.8 mm
Depth
71.5 mm
Color
green (RAL 6021)
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Shock
25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)
5g
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37
Sulfur dioxide (SO
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Conformance with EMC directives
Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion A, all interfaces ±1 kVCriterion B, all interfaces ±2 kV Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0 kV Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 Class A
Mounting type
DIN rail mounting

Specifications may be subject to change without notice