Selling Points

  • 1Precision Temperature Measurement: Measures temperatures from 0 to 400°C, 0 to 800°C, 0 to 1000°C, and 0 to 1200°C.
  • 2Configurable via DIP Switch: Easily adjust settings using a DIP switch for customized applications.
  • 3Electrically Isolated Input: Ensures safe and reliable operation by isolating the input signal.
  • 40-20 mA Output Signal: Provides a standard output signal for easy integration into various systems.
  • 5UL and cUL Recognized: Meets safety standards with UL and cUL recognition for reliable performance.
Product Details
MCR-TE-JK-I-E
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Temperature transmitter
Alignment span
± 5 % (of final value)
Alignment zero
± 60 K
Limit frequency (3 dB)
30 Hz
Typical cold point errors
± 2.5 K
Cold point error, max.
± 4 K
Test voltage input/output
1.5 kV AC (50 Hz, 60 s)
Test voltage input/power supply
1.5 kV AC (50 Hz, 60 s)
Step response (10-90%)
 11 ms
Maximum temperature coefficient
< 0.02 %/K
Maximum transmission error
≤ 1.2 % (of end value, for type K) < 2 % (of end value, for type J, 0 °C ... 400°C and 0 °C ... 800°C) < 2.5 % (of end value, for type J, 0 °C ... 1000°C and 0 °C ... 1200°C)
Supply voltage range
18 V DC ... 30 V DC
Max. current consumption
50 mA
Input signal
Temperature
Configurable/programmable
Yes
Sensor types that can be used (TC)
J, K
Temperature measuring range
0 °C ... 400 °C 0 °C ... 800 °C 0 °C ... 1000 °C 0 °C ... 1200 °C
Sensor type:
0 °C ... 400 °C (fixed setting) 0 °C ... 800 °C (fixed setting) 0 °C ... 1000 °C (fixed setting) 0 °C ... 1200 °C (fixed setting) 0 °C ... 400 °C (fixed setting) 0 °C ... 800 °C (fixed setting) 0 °C ... 1000 °C (fixed setting) 0 °C ... 1200 °C (fixed setting)
Configurable/programmable
Yes
Current output signal
0 mA ... 20 mA 4 mA ... 20 mA
Max. current output signal
30 mA
Output current with wire break
> 22 mA
Load/output load current output
≤ 500 Ω
Connection method
Pluggable screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section rigid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Width
17.5 mm
Height
99 mm
Depth
114.5 mm
Color
green (RAL 6021)
Housing material
Polyamide PA non-reinforced
Ambient temperature (operation)
-20 °C ... 65 °C
Certificate
CE-compliant
Identification
cULus
Mounting position
any

Specifications may be subject to change without notice