Phoenix Contact MINI MCR-2-UI-I-OLP-PT-C

Selling Points

  • 1Compact Design: 6.2 mm width, 110.5 mm height, and 120.5 mm depth for easy installation in confined spaces.
  • 2Versatile Input Range: Supports standard and non-standard analog signals from 2 mA or 50 mV to 40 mA or 30 V.
  • 3Flexible Configuration: Input signals configurable via DIP switches for customized settings.
  • 4High Safety Standards: Approval for Ex-zone 2 (nA) and reinforced insulation in accordance with IEC 61010-1.
  • 5Reliable Operation: 15 ms step response and minimal deviations under noise immunity conditions (EN 61000-6-2).
Product Details
MINI MCR-2-UI-I-OLP-PT-C
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Signal conditioner
Product family
MINI Analog Pro
No. of channels
1
Type
Signal conditioner
Configuration
DIP switches
Article revision
04
Overvoltage category
II
Pollution degree
2
Electrical isolation
2-way isolation
Electrical isolation between input and output
yes
Limit frequency (3 dB)
approx. 30 Hz
Step response (10-90%)
20 ms
Maximum temperature coefficient
0.01 %/K
Temperature coefficient, typical
0.005 %/K
Maximum transmission error
≤ 0.1 % (of final value)
Rated insulation voltage
300 V
Test voltage
3 kV AC (50 Hz, 60 s)
Insulation
Reinforced insulation according to IEC/EN 61010-1
Supply voltage range
8 V DC ... 30 V DC (loop-powered, no external supply necessary)
Typical current consumption
≤ 20 mA
Power consumption
≤ 600 mW
Number of inputs
1
Configurable/programmable
Yes
Voltage input signal
0 mV ... 1000 mV 0 mV ... 750 mV 0 mV ... 500 mV 0 mV ... 300 mV 0 mV ... 250 mV 0 mV ... 200 mV 0 mV ... 125 mV 0 mV ... 120 mV 0 mV ... 150 mV 0 mV ... 100 mV 0 mV ... 75 mV 0 mV ... 60 mV 0 mV ... 50 mV 0 V ... 10 V 0 V ... 7.5 V 0 V ... 5 V 0 V ... 3 V 0 V ... 2.5 V 0 V ... 2 V 0 V ... 1.5 V 0 V ... 1.25 V 0 V ... 1.2 V 0 V ... 30 V 0 V ... 25 V 0 V ... 20 V 0 V ... 12.5 V 0 V ... 12 V 0 V ... 15 V -1000 mV ... 1000 mV -750 mV ... 750 mV -500 mV ... 500 mV -300 mV ... 300 mV -250 mV ... 250 mV -200 mV ... 200 mV -125 mV ... 125 mV -120 mV ... 120 mV -150 mV ... 150 mV -100 mV ... 100 mV -75 mV ... 75 mV -60 mV ... 60 mV -50 mV ... 50 mV -10 V ... 10 V -7.5 V ... 7.5 V -5 V ... 5 V -3 V ... 3 V -2.5 V ... 2.5 V -2 V ... 2 V -1.25 V ... 1.25 V -1.2 V ... 1.2 V -1.5 V ... 1.5 V -30 V ... 30 V -25 V ... 25 V -20 V ... 20 V -12.5 V ... 12.5 V -12 V ... 12 V -15 V ... 15 V 2 V ... 10 V (additional areas can be configured, see table) 1 V ... 5 V (additional areas can be configured, see table)
Max. voltage input signal
< 30 V
Current input signal
0 mA ... 40 mA 0 mA ... 30 mA 0 mA ... 20 mA 0 mA ... 12 mA 0 mA ... 10 mA 0 mA ... 8 mA 0 mA ... 7.5 mA 0 mA ... 6 mA 0 mA ... 5 mA 0 mA ... 4 mA 0 mA ... 3 mA 0 mA ... 2.5 mA 0 mA ... 2 mA 4 mA ... 20 mA 2 mA ... 10 mA 1 mA ... 5 mA
Max. current input signal
50 mA (Dielectric strength up to 30 V)
Input resistance of voltage input
 100 kΩ (≤ 1 V)  1 MΩ (≥ 1 V)
Input resistance current input
25 Ω (+0.7 V for test diode)
Number of outputs
1
Current output signal
4 mA ... 20 mA
Max. current output signal
32 mA
Load/output load current output
< 1000 Ω ((U
Ripple
< 10 mV
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section rigid
0.2 mm² ... 2.5 mm² (with ferrule) 0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 12 (flexible)
Ex installation (EPL)
Gc Div. 2
Status display
Green LED (supply voltage)
Width
6.2 mm
Height
109.81 mm
Depth
119.2 mm
Color
gray (RAL 7042)
Housing material
PBT
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 2
Degree of protection
IP20 (not assessed by UL)
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 2000 m
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Certificate
CE-compliant
Identification
 II 3 G Ex ec IIC T4 Gc
Certificate
BVS 19 ATEX E 079 X
Identification
 II 3 G Ex ec IIC T4 Gc
Certificate
PxCIF21UKEX2901994X
Identification
Ex ec IIC T4 Gc
Certificate
IECEx BVS 19.0068X
Identification
Ex nA IIC T4 Gc
Identification
UL 508 Listed Class I, Div. 2, Groups A, B, C, D T5 Class I, Zone 2, Group IIC T5
Certificate
DNV GL TAA000021E Rev. 1
Identification
 2Ex ec IIC T4 Gc
Certificate
BY/112 02.01 TP012 103.01 00081
Temperature
B
Humidity
B
Vibration
A
EMC
A
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Noise immunity
EN 61000-6-2
Note
When being exposed to interference, there may be minimal deviations.
Noise emission
EN 61000-6-4
Electrical isolation
2-way isolation
Standards/regulations
GB 3836.1 GB 3836.8
Mounting type
DIN rail mounting
Mounting position
any

Specifications may be subject to change without notice