Product Model

MINI MCR-RTD-UI-SP-NC

In Stock
Last updated: 2025/4/18
Phoenix Contact MINI MCR-RTD-UI-SP-NC

Selling Points

  • 1Configurable via DIP switches or software for easy setup.
  • 2Supports 3-way isolation for reliable electrical separation.
  • 3Compatible with Pt, Ni, and Cu sensors for various temperature ranges.
  • 4Fault monitoring capabilities ensure continuous system reliability.
  • 5Linear current or voltage signal conversion for precise measurement.
Product Details
MINI MCR-RTD-UI-SP-NC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Temperature transmitter
Product family
MINI Analog
Article revision
06
Overvoltage category
II
Pollution degree
2
Rated insulation voltage
50 V AC/DC
Electrical isolation
Basic insulation in accordance with EN 61010
Test voltage, input/output/supply
1.5 kV (50 Hz, 1 min.)
Protective circuit
Transient protection
Step response (0–99%)
200 ms (2-conductor) 500 ms (3-conductor) 500 ms (4-conductor)
Maximum temperature coefficient
0.01 %/K
Transmission error resistance-type sensor
2 Ω
Transmission error resistance thermometer
0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni) 0.3 % * 200 K / set measuring range; 0.3 % > 200 K (Cu)
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption
< 27 mA (at 24 V DC)
Power consumption
≤ 700 mW (at I
Number of inputs
1
Input signal
Temperature Resistor
Configurable/programmable
Yes
Sensor types (RTD) that can be used
Pt, Ni, Cu sensors: 2, 3, 4-wire
Temperature measuring range
-200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
Temperature measuring range
min. 50 K
Sensor input current
approx. 200 µA
Max. permissible overall conductor resistance
≤ 25 Ω (Per cable)
Linear resistance measuring range
0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
Connection technology
2-, 3-, 4-conductor
Configurable/programmable
no
Number of outputs
1
Configurable/programmable
Yes
Voltage output signal
0 V ... 10 V 10 V ... 0 V 0 V ... 5 V 1 V ... 5 V
Max. voltage output signal
approx. 12.3 V
Current output signal
0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA
Max. current output signal
24.6 mA
Load/output load voltage output
10 kΩ
Load/output load current output
500 Ω (at 20 mA)
Ripple
< 20 mV < 20 mV
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 12
Connection method
S-PORT
Status display
LED (red)
Width
6.2 mm
Height
93.1 mm
Depth
102.5 mm
Color
green (RAL 6021)
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 2
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 65 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Certificate
CE-compliant
Identification
 II 3 G Ex nA IIC T4 Gc X
Identification
UL 508 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC
Identification
D, EMC1
Certificate
DNV GL 14085-15HH
Electromagnetic compatibility
Conformance with EMC directive
Noise immunity
EN 61000-6-2
Note
When being exposed to interference, there may be minimal deviations.
Noise emission
EN 61000-6-4
Standards/regulations
EN 61000-4-2
Comments
Safety measures must be taken to prevent electrostatic discharge.
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
0.04 %
Designation
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
0.1 %
Standards/regulations
EN 61000-4-5
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
0.02 %
Electrical isolation
Basic insulation in accordance with EN 61010
Mounting type
DIN rail mounting
Assembly note
The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting position
any

Specifications may be subject to change without notice