Phoenix Contact MINI MCR-SL-PTB

Selling Points

  • 1Two separate voltage inputs ensure continuous power supply with a maximum current of 2 A.
  • 2Green and red LEDs indicate status and polarity, ensuring correct connection and operation.
  • 3Snap-on design for easy mounting on 35 mm DIN rails according to EN 60715.
  • 4Supports up to 2 A of current, ideal for various industrial applications.
  • 5Meets EMC Directive 2004/108/EC and other international standards for electromagnetic compatibility.
Product Details
MINI MCR-SL-PTB
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Power module
Product family
MINI Analog
Article revision
09
Input voltage range DC
20 V DC ... 30 V DC
Max. input current
2 A
Reverse polarity protection
yes
Output voltage range
Input voltage - 0.8 V
Connection method
Screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
26
Conductor cross section AWG max.
12
Stripping length
12 mm
Screw thread
M3
Status display
Green LED (supply)
Error indication
Red LED
Width
6.2 mm
Height
93.1 mm
Depth
102.5 mm
Housing material
PBT
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 2
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 65 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Maximum altitude
≤ 2000 m
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Certificate
CE-compliant
Certificate
UKCA-compliant
Identification
UL 508 Listed
Certificate
DNV GL TAA000020N
Temperature
B
Humidity
B
Vibration
B
EMC
A
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Noise immunity
EN 61000-6-2
Note
When being exposed to interference, there may be minimal deviations.
Noise emission
EN 61000-6-4
Standards/regulations
EN 61000-4-2
Comments
Safety measures must be taken to prevent electrostatic discharge.
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Evaluation criterion
A
Designation
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Evaluation criterion
B
Standards/regulations
EN 61000-4-5
Comments
Criterion B
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Evaluation criterion
A
Mounting type
DIN rail mounting
Assembly note
The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting position
any

Specifications may be subject to change without notice