- 1Configurable via DIP switches or software for flexible setup.
- 2Wide compatibility with thermocouples (J, K, IEC 584-1).
- 3High accuracy with typical cold point errors < 2 K.
- 4Robust design with transient protection and IP20 rating.
- 5Compact dimensions (6.2 mm width, 93.1 mm height) for easy integration.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
EMC note | EMC: class A product, see manufacturer's declaration in the download area | Product type | Temperature transmitter |
Product family | MINI Analog | No. of channels | 1 |
Overvoltage category | II | Pollution degree | 2 |
Rated insulation voltage | 50 V AC/DC | Electrical isolation | Basic insulation in accordance with EN 61010 |
Typical cold point errors | < 2 K | Cold point error, max. | < 3 K |
Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) | Protective circuit | Transient protection |
Step response (0–99%) | < 30 ms | Maximum temperature coefficient | < 0.02 %/K |
Transmission error in the set measuring range | ((150 K / set measurement range [K]) + 0.1)% | Transmission error in the full measuring range | ≤ 0,2 % |
Nominal supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Max. current consumption | < 25 mA (at 24 V DC) | Power consumption | < 500 mW |
Number of inputs | 1 | Input signal | Temperature |
Sensor types that can be used (TC) | Thermocouples type J, K (IEC 584-1) | Temperature measuring range | min. 50 K |
Sensor type: | -150 °C ... 1200 °C (configurable)
-150 °C ... 1350 °C | Number of outputs | 1 |
Voltage output signal | 0 V ... 10 V
10 V ... 0 V
0 V ... 5 V
1 V ... 5 V | Max. voltage output signal | approx. 12.5 V |
Non-load voltage | approx. 12.5 V | Current output signal | 0 mA ... 20 mA (please indicate if different setting when ordering)
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA |
Max. current output signal | 23 mA | Short-circuit current | approx. 10 mA |
Load/output load voltage output | ≥ 10 kΩ | Load/output load current output | < 500 Ω (at 20 mA) |
Ripple | < 20 mV
< 20 mV | Connection method | Screw connection |
Stripping length | 12 mm | Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² | Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 12 | Width | 6.2 mm |
Height | 93.1 mm | Depth | 102.5 mm |
Color | green (RAL 6021) | Housing material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 | Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 | Degree of protection | IP20 |
Ambient temperature (operation) | -20 °C ... 65 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Certificate | CE-compliant | Identification | II 3 G Ex nA IIC T4 Gc X |
Identification | UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 | Identification | GL EMC 2 D |
Electromagnetic compatibility | Conformance with EMC directive | Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. | Noise emission | EN 61000-6-4 |
Standards/regulations | EN 61000-4-2 | Comments | Safety measures must be taken to prevent electrostatic discharge. |
Designation | Electromagnetic RF field | Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 10 % | Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 | Typical deviation from the measuring range final value | 10 % |
Standards/regulations | EN 61000-4-5 | Comments | Criterion B |
Designation | Conducted interferences | Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 10 % | Electrical isolation | Basic insulation in accordance with EN 61010 |
Mounting type | DIN rail mounting | Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting position | any |