- 1Configurable 3-way isolating amplifier for electrical isolation, conversion, amplification, and filtering of standard signals.
- 2Adjustable input/output signal ranges via DIP switches, accommodating 0...24 V and 0...30 V inputs, and 0...20 mA, 4...20 mA, 0...10 V, 2...10 V, 0...5 V, or 1...5 V outputs.
- 3Highly compact design with a width of 6.2 mm, ideal for space-constrained applications.
- 4Low power consumption with a maximum current consumption of <19 mA at 24 V DC and total power consumption of <450 mW.
- 5Compliant with safety standards, including approval for Ex-zone 2 (nA) and basic insulation according to EN 61010.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Signal conditioner | Product family | MINI Analog |
No. of channels | 1 | Article revision | 05 |
Overvoltage category | II | Pollution degree | 2 |
Rated insulation voltage | 50 V AC/DC | Electrical isolation | Basic insulation in accordance with EN 61010 |
Electrical isolation between input and output | yes | Limit frequency (3 dB) | approx. 100 Hz |
Maximum power dissipation for nominal condition | 58 mW | Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) |
Protective circuit | Transient protection | Step response (10-90%) | 3.5 ms |
Maximum temperature coefficient | < 0.01 %/K | Temperature coefficient, typical | < 0.002 %/K |
Maximum transmission error | < 0.1 % (of final value)
< 0.4 % (Without adjustment) | Nominal supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) | Max. current consumption | < 19 mA (at 24 V DC incl. load) |
Power consumption | < 450 mW | Number of inputs | 1 |
Configurable/programmable | Yes, unconfigured | Voltage input signal | 0 V ... 24 V
0 V ... 30 V |
Max. voltage input signal | 50 V DC | Input resistance of voltage input | approx. 125 kΩ (0 ... 24 V)
approx. 155 kΩ (0 V ... 30 V) |
Number of outputs | 1 | Configurable/programmable | Yes, unconfigured |
Voltage output signal | 0 V ... 10 V
0 V ... 5 V
1 V ... 5 V
2 V ... 10 V | Max. voltage output signal | ≤ 12.5 V |
Non-load voltage | ≤ 12.5 V | Current output signal | 0 mA ... 20 mA
4 mA ... 20 mA |
Max. current output signal | 28 mA | Short-circuit current | ≤ 22 mA |
Load/output load voltage output | > 10 kΩ | Load/output load current output | < 500 Ω (at 20 mA) |
Ripple | < 20 mV
< 20 mV | Connection method | Spring-cage connection |
Stripping length | 8 mm | Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² | Conductor cross section AWG | 24 ... 12 |
Width | 6.2 mm | Height | 93.1 mm |
Depth | 102.5 mm | Color | green (RAL 6021) |
Housing material | PBT | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Degree of protection | IP20 | Ambient temperature (operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C | Electromagnetic compatibility | Conformance with EMC directive |
Noise immunity | EN 61000-6-2 | Note | When being exposed to interference, there may be minimal deviations. |
Noise emission | EN 61000-6-4 | Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. | Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 | Typical deviation from the measuring range final value | 5 % |
Designation | Fast transients (burst) | Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 5 % | Standards/regulations | EN 61000-4-5 |
Comments | Criterion B | Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 | Typical deviation from the measuring range final value | 5 % |
Electrical isolation | Basic insulation in accordance with EN 61010 | Mounting type | DIN rail mounting |
Assembly note | The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715. | Mounting position | any |
Specifications may be subject to change without notice