Phoenix Contact MINI MCR-TC-UI-NC

Selling Points

  • 1Configurable via DIP switches or software for flexible setup.
  • 23-way electrical isolation ensures safe and reliable operation.
  • 3Wide temperature range from -250°C to 2500°C, accommodating diverse applications.
  • 4High accuracy with typical cold point errors less than 2 K.
  • 5Compact design with dimensions (W/H/D) 6.2 mm / 93.1 mm / 102.5 mm, ideal for DIN rail mounting.
Product Details
MINI MCR-TC-UI-NC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Temperature transmitter
Product family
MINI Analog
Configuration
DIP switches Software
Article revision
13
Overvoltage category
II
Pollution degree
2
Electrical isolation
3-way isolation
Typical cold point errors
< 2 K
Cold point error, max.
< 3 K
Protective circuit
Transient protection
Step response (0–99%)
400 ms (Highspeed Mode: typ. 150 ms)
Maximum temperature coefficient
≤ 0.01 %/K
Transmission error thermocouples
0.1 % * 600 K / set measuring range; 0.1 % > 600 K (E, J, K, N, T, L, U, M Gost, L Gost) 0.2 % * 600 K / set measuring range; 0.2 % > 600 K (B, R, S, A1, A2, A3) 0.2% * 600 K / set measuring range; 0.2% > 600 K (E, J, K, N, T, L, U, M Gost, L Gost); Highspeed Mode 0.4% * 600 K / set measuring range; 0.4% > 600 K (B, R, S, A1, A2, A3); Highspeed Mode
Rated insulation voltage
50 V AC/DC
Test voltage
1.5 kV AC (50 Hz, 60 s)
Insulation
Basic insulation in accordance with IEC/EN 61010
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption
< 27 mA (at 24 V DC)
Max. current consumption
72 mA
Power consumption
≤ 700 mW (at I
Number of inputs
1
Number of inputs
1
Configurable/programmable
Yes
Sensor types that can be used (TC)
B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range
-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
Temperature measuring range
min. 50 K
Sensor type:
500 °C ... 1820 °C -230 °C ... 1000 °C -210 °C ... 1200 °C -250 °C ... 1372 °C -200 °C ... 1300 °C -50 °C ... 1768 °C -50 °C ... 1768 °C -200 °C ... 400 °C -200 °C ... 900 °C -200 °C ... 600 °C 0 °C ... 2500 °C 0 °C ... 1800 °C 0 °C ... 1800 °C -200 °C ... 100 °C -200 °C ... 800 °C
Number of outputs
1
Configurable/programmable
Yes
Voltage output signal
0 V ... 5 V 1 V ... 5 V 0 V ... 10 V 10 V ... 0 V
Max. voltage output signal
approx. 12.3 V
Non-load voltage
< 17.5 V
Current output signal
0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA
Max. current output signal
24.6 mA
Short-circuit current
< 31.5 mA
Load/output load voltage output
≥ 10 kΩ
Load/output load current output
< 500 Ω (at 20 mA)
Ripple
< 20 mV < 20 mV
Connection method
Screw connection
Stripping length
12 mm
Screw thread
M3
Conductor cross section rigid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 12
Connection method
S-PORT
Status display
LED (red)
Width
6.2 mm
Height
93.1 mm
Depth
101.2 mm
Color
green (RAL 6021)
Housing material
PBT
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 2
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 65 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 2000 m
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Certificate
CE-compliant
Certificate
UKCA-compliant
Identification
UL 508 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC
Certificate
DNV GL TAA00002R0
Temperature
B
Humidity
B
Vibration
B
EMC
A
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Noise immunity
EN 61000-6-2
Note
When being exposed to interference, there may be minimal deviations.
Noise emission
EN 61000-6-4
Standards/regulations
EN 61000-4-2
Comments
Safety measures must be taken to prevent electrostatic discharge.
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
0.15 %
Designation
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
0.05 %
Standards/regulations
EN 61000-4-5
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
0.02 %
Electrical isolation
3-way isolation
Mounting type
DIN rail mounting
Mounting position
any

Specifications may be subject to change without notice