Product Model
PLC-BSC-230UC/ 1/SEN/SO46

Selling Points
- 1High relay release voltage for reliable switching.
- 2Interference current and voltage protection on the control side.
- 3Compact dimensions (6.2 mm width, 80 mm height) for space-constrained installations.
- 4Easy DIN rail mounting with flexible mounting positions.
- 5Operating efficiently within ambient temperatures -40 °C to 55 °C.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
EMC note | EMC: class A product, see manufacturer's declaration in the download area | Product type | Relay socket |
Product family | PLC-INTERFACE | Application | Filter to prevent interference |
Operating mode | 100% operating factor | Compatible components | Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1 |
Article revision | 12 | Pollution degree | 3 |
Protective circuit | Bridge rectifier; Bridge rectifier
RCZ filter; RCZ filter | Nominal input voltage U | 230 V AC
The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit
230 V AC
The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit |
Nominal input voltage U | 230 V AC | Input voltage range in reference to U | 0.78 ... 1.14 |
Typical input current at U | 8.8 mA (50 Hz)
10 mA (60 Hz) | Typical response time | 7 ms |
Typical release time | 20 ms | Typical release voltage | 80 V AC |
Operating voltage display | Yellow LED | Protective circuit | Bridge rectifier; Bridge rectifier
Filter; Filter |
Nominal input voltage U | 230 V AC | Input voltage range in reference to U | 0.8 ... 1.1 |
Typical input current at U | 8.8 mA
10 mA | Switching threshold "0" signal in reference to U | ≤ 0.4 |
Typical response time | 6 ms | Typical release time | 10 ms |
Operating voltage display | Yellow LED | Protective circuit | Bridge rectifier; Bridge rectifier
Filter; Filter |
Compatible components | Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1 | Maximum switching voltage | 48 V DC |
Minimum switching voltage | 3 V DC | Limiting continuous current | 100 mA |
Voltage drop at max. limiting continuous current | < 1 V DC | Output circuit | 2-conductor, floating |
Protective circuit | Reverse polarity protection
Surge protection | Maximum switching voltage | 30 V DC |
Minimum switching voltage | 3 V DC | Limiting continuous current | 3 A |
Voltage drop at max. limiting continuous current | < 200 mV | Maximum inrush current | 15 A (10 ms) |
Output circuit | 2-conductor, floating | Protective circuit | Reverse polarity protection
Surge protection |
Maximum switching voltage | 253 V AC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) | Minimum switching voltage | 24 V AC |
Limiting continuous current | 0.75 A | Voltage drop at max. limiting continuous current | < 1 V AC |
Maximum inrush current | 30 A (10 ms) | Output circuit | 2-conductor, floating |
Protective circuit | RCV circuit | Leakage current | < 1 mA |
Phase angle cos phi min | 0.5 | Max. load value | 4.5 A |
Connection method | Screw connection | Stripping length | 8 mm |
Screw thread | M3 | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) | Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing)) | Status display | LED |
Width | 6.2 mm | Height | 80 mm |
Depth | 94 mm | Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) | Ambient temperature (operation) | -40 °C ... 55 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C | Certificate | CE-compliant |
Certificate | UKCA-compliant | Certificate | TAE0000196 |
Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 | Temperature | D |
Humidity | A | Vibration | B/C |
EMC | B | Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC directive | Low Voltage Directive | Conformance with Low Voltage Directive |
Mounting type | DIN rail mounting | Assembly note | in rows with zero spacing |
Mounting position | any |
Specifications may be subject to change without notice