Product Model
PLC-OSC-120UC/ 48DC/100

Selling Points
- 1Reliable Signal Conversion: Converts 120 V AC/110 V DC inputs to 3-48 V DC outputs with high accuracy.
- 2Explosive Area Compliance: Meets Class I, Division 2 and Ex Zone Class I standards for use in potentially explosive areas.
- 3High Operating Factor: Operates at a 100% operating factor, ensuring consistent performance.
- 4Basic Insulation and Overvoltage Protection: Features basic insulation and overvoltage category III for enhanced safety.
- 5Compact Design: Compact dimensions (6.2 mm width, 80 mm height, 94 mm depth) for easy DIN rail mounting.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Solid-state relay module | Product family | PLC-INTERFACE |
Application | Universal | Operating mode | 100% operating factor |
Date of last data management | 07.05.2024 | Article revision | 10 |
Insulation | Basic insulation | Overvoltage category | III |
Pollution degree | 2 | Maximum power dissipation for nominal condition | 0.42 W |
Test voltage (Input/output) | 2.5 kV (50 Hz, 1 min., input/output) | Nominal input voltage U | 120 V AC
110 V DC |
Nominal voltage (plugged-in solid-state relay) | 60 V DC | Input voltage range in reference to U | 0.9 ... 1.1 |
Input voltage range | 108 V AC ... 132 V AC
99 V DC ... 121 V DC | Switching threshold "0" signal in reference to U | ≤ 0.3 |
Switching threshold "1" signal in reference to U | ≥ 0.9 | Typical input current at U | 3.5 mA |
Typical response time | 3 ms (at U | Typical turn-off time | 4 ms (at U |
Operating voltage display | Yellow LED | Protective circuit | Bridge rectifier; Bridge rectifier |
Transmission frequency | 10 Hz | Contact switching type | 1 N/O contact |
Design of digital output | electronic | Output voltage range | 3 V DC ... 48 V DC |
Limiting continuous current | 100 mA | Voltage drop at max. limiting continuous current | ≤ 1 V |
Output circuit | 2-conductor, floating | Protective circuit | Reverse polarity protection; Polarity protection diode
Surge protection |
Connection method | Screw connection | Stripping length | 8 mm |
Screw thread | M3 | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) | Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.6 Nm ... 0.8 Nm | Width | 6.2 mm |
Height | 80 mm | Depth | 94 mm |
Color | gray (RAL 7042) | Flammability rating according to UL 94 | V0 (Housing) |
Ambient temperature (operation) | -25 °C ... 60 °C | Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Certificate | CE-compliant | Certificate | UKCA-compliant |
Certificate | TAE0000196 | Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 |
Temperature | D | Humidity | A |
Vibration | B/C | EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board | Electromagnetic compatibility | Conformance with EMC directive |
Low Voltage Directive | Conformance with Low Voltage Directive | Standards/regulations | IEC 60947-5-1 |
Mounting type | DIN rail mounting | Assembly note | in rows with zero spacing |
Mounting position | any |