Product Model
PLC-OSC- 24DC/ 24DC/ 2/ACT

Selling Points
- 1Directly connect to system cabling using the V8 adapter for streamlined setup.
- 2Achieve quick switching times with a typical response time of 20 µs and turn-off time of 300 µs.
- 3Ensure reliable operation with reverse polarity protection, free-wheeling diode, and surge protection.
- 4Operate within a wide input voltage range of 19.2 V DC to 28.8 V DC.
- 5Compact dimensions (6.2 mm x 80 mm x 94 mm) for easy integration into industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Solid-state relay module | Product family | PLC-INTERFACE |
Application | Output function | Operating mode | 100% operating factor |
Date of last data management | 07.05.2024 | Article revision | 10 |
Insulation | Basic insulation | Overvoltage category | III |
Pollution degree | 2 | Maximum power dissipation for nominal condition | 0.2 W |
Test voltage (Input/output) | 2.5 kV (50 Hz, 1 min., input/output) | Nominal input voltage U | 24 V DC |
Nominal voltage (plugged-in solid-state relay) | 24 V DC | Input voltage range in reference to U | 0.8 ... 1.2 |
Input voltage range | 19.2 V DC ... 28.8 V DC | Switching threshold "0" signal in reference to U | ≤ 0.4 |
Switching threshold "1" signal in reference to U | ≥ 0.8 | Typical input current at U | 8.5 mA |
Typical response time | 20 µs (at U | Typical turn-off time | 300 µs (at U |
Operating voltage display | Yellow LED | Protective circuit | Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode |
Transmission frequency | 300 Hz | Contact switching type | 1 N/O contact |
Design of digital output | electronic | Contact connection type | Power contact |
Output voltage range | 3 V DC ... 33 V DC | Limiting continuous current | 3 A (see derating curve) |
Maximum inrush current | 15 A (10 ms) | Voltage drop at max. limiting continuous current | ≤ 200 mV |
Output circuit | 2-conductor, floating | Protective circuit | Reverse polarity protection; Polarity protection diode
Surge protection |
Connection method | Screw connection | Stripping length | 8 mm |
Screw thread | M3 | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) | Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.6 Nm ... 0.8 Nm | Width | 6.2 mm |
Height | 80 mm | Depth | 94 mm |
Flammability rating according to UL 94 | V0 (Housing) | Ambient temperature (operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -25 °C ... 70 °C | Certificate | CE-compliant |
Certificate | UKCA-compliant | Certificate | TAE0000196 |
Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 | Temperature | D |
Humidity | A | Vibration | B/C |
EMC | B | Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC directive | Low Voltage Directive | Conformance with Low Voltage Directive |
Standards/regulations | IEC 60947-5-1 | Mounting type | DIN rail mounting |
Assembly note | in rows with zero spacing | Mounting position | any |
Specifications may be subject to change without notice