Phoenix Contact PLC-OSC- 60DC/300DC/  1

Selling Points

  • 1Designed for seamless operation with an integrated solid-state relay.
  • 2Operates from 48 V DC to 72 V DC, ensuring versatility in various industrial settings.
  • 3Features a rapid response time of 0.3 ms for quick and reliable switching.
  • 4Handles a limiting continuous current of 1 A, making it suitable for demanding applications.
  • 5Equipped with reverse polarity protection, surge protection, and a protective circuit for added reliability.
Product Details
PLC-OSC- 60DC/300DC/ 1
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Solid-state relay module
Product family
PLC-INTERFACE
Application
With integrated solid-state relay
Operating mode
100% operating factor
Date of last data management
16.09.2024
Article revision
11
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
0.3 W
Rated insulation voltage
300 V
Rated surge voltage
2.5 kV
Nominal input voltage U
60 V DC
Input voltage range in reference to U
0.8 ... 1.2
Input voltage range
48 V DC ... 72 V DC
Switching threshold "0" signal in reference to U
≤ 0.4
Switching threshold "1" signal in reference to U
≥ 0.8
Typical input current at U
5 mA
Typical response time
0.3 ms
Typical turn-off time
0.7 ms
Operating voltage display
Yellow LED
Protective circuit
Reverse polarity protection; Polarity protection diode Surge protection; Varistor
Transmission frequency
50 Hz
Designation
Output data
Contact switching type
1 N/O contact
Design of digital output
electronic
Output voltage range
12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Limiting continuous current
1 A (see derating curve)
Voltage drop at max. limiting continuous current
< 500 mV
Protective circuit
Reverse polarity protection; Polarity protection diode Surge protection; Varistor
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG
26 ... 14
Tightening torque
0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
Width
6.2 mm
Height
80 mm
Depth
94 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V0 (Housing)
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Certificate
CE-compliant
Certificate
UKCA-compliant
Certificate
TAE0000196
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Temperature
D
Humidity
A
Vibration
B/C
EMC
B
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Low Voltage Directive
Conformance with Low Voltage Directive
Standards/regulations
IEC 60947-5-1
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice