Phoenix Contact PLC-RPT- 24DC/2X21/FG

Selling Points

  • 1UL 508 Certified: Meets stringent safety standards for industrial control equipment.
  • 2Force-Guided Contacts: Ensures reliable switching with AgNi contacts in accordance with DIN EN 50205.
  • 324 V DC Input: Compatible with a wide range of industrial power supplies.
  • 4High Switching Performance: Typical response time of 10 ms and release time of 10 ms.
  • 5Durable Construction: Designed for 10^7 cycles of operation, ensuring long-lasting performance.
Product Details
PLC-RPT- 24DC/2X21/FG
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Relay Module
Product family
PLC-INTERFACE
Application
Forcibly guided contacts
Operating mode
100% operating factor
Mechanical service life
approx. 10
B
600000 Cycles (AC1; 250 V / 6 A; 1 NO) 900000 Cycles (AC1; 250 V / 3 A; 1 NO) 1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO) 180000 Cycles (AC15; 250 V / 3 A; 1 NO) 560000 Cycles (AC15; 250 V / 2 A; 1 NO) 4600000 Cycles (AC15; 250 V / 0,75 A; 1 NO) 360000 Cycles (DC13; 24 V / 3 A; 1 NO) 740000 Cycles (DC13; 24 V / 1,5 A; 1 NO) 4200000 Cycles (DC13; 24 V / 0,75 A; 1 NO)
Date of last data management
08.07.2024
Article revision
03
Insulation
Safe isolation, reinforced insulation
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
0.72 W
Test voltage (Winding/contact)
4 kV
Test voltage (Changeover contact/changeover contact)
2.5 kV
Rated insulation voltage
250 V AC
Rated surge voltage
6 kV
Nominal input voltage U
24 V DC
Input voltage range
20.2 V DC ... 32.4 V DC (20 °C)
Input voltage range in reference to U
see diagram
Nominal voltage (plugged-in electromechanical relay)
24 V DC
Drive and function
monostable
Drive (polarity)
polarized
Typical input current at U
30 mA
Typical response time
10 ms
Typical release time
10 ms
Protective circuit
Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
2 changeover contacts, forcibly actuated
Type of switch contact
Single contact
Contact material
AgNi
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
5 V (10 mA)
Limiting continuous current
6 A
Maximum inrush current
6 A
Min. switching current
10 mA (5 V)
Interrupting rating (ohmic load) max.
144 W (24 V DC) 288 W (48 V DC) 88 W (110 V DC) 110 W (220 V DC) 1500 VA (250 V AC)
Switching capacity min.
150 mW
Switching capacity
3 A (24 V, DC13) 3 A (230 V, AC15)
Force-guided contacts in accordance with EN 61810-3
Type B
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG
26 ... 14
Width
14 mm
Height
80 mm
Depth
104 mm
Color
gray (RAL 7042)
Degree of protection (Relay)
RT II (Relay)
Degree of protection (Relay base)
IP20 (Relay base)
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
-20 °C ... 60 °C
Ambient temperature (storage/transport)
-20 °C ... 85 °C
Altitude
≤ 2000 m
Certificate
CE-compliant
Certificate
UKCA-compliant
Identification
UL 508 UL 508 Recognized
Identification
UL 508 UL 508 Recognized
Certificate
TAE0000196
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Temperature
D
Humidity
A
Vibration
B/C
EMC
B
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Low Voltage Directive
Conformance with Low Voltage Directive
Standards/regulations
IEC 60947-5-1 DIN EN 61810-3
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice