Product Model

PLC-RPT- 48UC/21AU

In Stock
Last updated: 2025/4/26
Phoenix Contact PLC-RPT- 48UC/21AU

Selling Points

  • 1Simplify your system cabling with the V8 adapter for easy and secure connections.
  • 2Conveniently mount the relay module on DIN rails for versatile installation options.
  • 3Ensure reliable operation with reverse polarity protection and a polarity protection diode.
  • 4Suitable for a wide range of applications with a nominal input voltage of 48V DC.
  • 5Achieve quick switching with a typical response time of 5 ms and release time of 8 ms.
Product Details
PLC-RPT- 48UC/21AU
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Relay Module
Product family
PLC-INTERFACE
Operating mode
100% operating factor
Mechanical service life
approx. 3x 10
Date of last data management
08.07.2024
Article revision
04
Insulation
Basic insulation
Maximum power dissipation for nominal condition
0.48 W
Test voltage (Winding/contact)
4 kV AC (50 Hz, 1 min., winding/contact)
Rated insulation voltage
250 V AC
Rated surge voltage
4 kV
Nominal input voltage U
48 V AC/DC (50/60 Hz)
Input voltage range
38.4 V AC/DC ... 60 V AC/DC (20 °C)
Nominal voltage (plugged-in electromechanical relay)
24 V DC
Drive and function
monostable
Drive (polarity)
polarized
Typical input current at U
10 mA (At U 9.2 mA (At U
Typical response time
6 ms
Typical release time
15 ms
Protective circuit
Bridge rectifier; Bridge rectifier
Operating voltage display
Yellow LED
Contact switching type
1 changeover contact
Type of switch contact
Single contact
Contact material
AgSnO, hard gold-plated
Note
If the specified maximum values are exceeded, the gold plating is destroyed. The AgNi contact values are then valid for further operation; a reduction in length of service life is to be expected.
Maximum switching voltage
30 V AC 36 V DC
Minimum switching voltage
100 mV (at 10 mA)
Limiting continuous current
50 mA
Maximum inrush current
50 mA
Min. switching current
1 mA (24 V)
Short-circuit current
200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.
1.2 W (at 24 V DC)
Output fuse
4 A gL/gG NEOZED
Switching capacity
3 A (230 V (AC 15))
Note
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
5 V (at 100 mA)
Limiting continuous current
6 A
Min. switching current
10 mA (at 12 V)
Interrupting rating (ohmic load) max.
140 W (at 24 V DC) 20 W (at 48 V DC) 18 W (at 60 V DC) 23 W (at 110 V DC) 40 W (at 220 V DC) 1500 VA (for 250 V AC)
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG
26 ... 14
Width
6.2 mm
Height
80 mm
Depth
86 mm
Color
gray (RAL 7042)
Degree of protection (Relay base)
IP20 (Relay base)
Ambient temperature (operation)
-20 °C ... 60 °C
Ambient temperature (storage/transport)
-20 °C ... 60 °C
Certificate
CE-compliant
Certificate
UKCA-compliant
Certificate
TAE0000196
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Temperature
D
Humidity
A
Vibration
B/C
EMC
B
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Low Voltage Directive
Conformance with Low Voltage Directive
Standards/regulations
IEC 60947-5-1
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice