Product Model

PLC-RSC- 24DC/PMC T200/21HC

In Stock
Last updated: 2025/4/21
Phoenix Contact PLC-RSC- 24DC/PMC T200/21HC

Selling Points

  • 1100% operating factor ensures consistent performance.
  • 2Reinforced insulation with safe isolation between adjacent modules.
  • 3Compatible with 19.2 V DC to 26.4 V DC input voltage range.
  • 4Typical response time of 7 ms for quick switching.
  • 5Equipped with surge protection and freewheeling diode for reliability.
Product Details
PLC-RSC- 24DC/PMC T200/21HC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Relay Module
Product family
PLC-INTERFACE
Operating mode
100% operating factor
Mechanical service life
approx. 2x 10
Date of last data management
08.07.2024
Article revision
09
Insulation
Safe isolation, reinforced insulation (partition plate PLC-ATP should be installed for safe isolation between adjacent modules).
Overvoltage category
III
Pollution degree
3
Maximum power dissipation for nominal condition
0.4 W
Nominal input voltage U
24 V DC
Input voltage range
19.2 V DC ... 26.4 V DC (20 °C)
Nominal voltage (plugged-in electromechanical relay)
24 V DC
Typical input current at U
15 mA (Relay ON) 4.3 mA (Relay OFF)
Typical response time
7 ms
Typical release time
200 ms +130 ms (Typical interval time at U
Protective circuit
Surge protection; Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
Single contact, 1 changeover contact
Type of switch contact
Single contact
Contact material
AgNi, hard gold-plated
Maximum switching voltage
250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage
12 V AC/DC
Limiting continuous current
10 A
Maximum inrush current
16 A
Min. switching current
100 mA
Interrupting rating (ohmic load) max.
240 W (at 24 V DC) 144 W (at 48 V DC) 48 W (at 60 V DC) 50 W (at 110 V DC) 80 W (at 220 V DC) 4000 W (for 250 V AC)
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG
26 ... 14
Tightening torque
0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
Width
14 mm
Height
80 mm
Depth
94 mm
Color
green (RAL 6021)
Flammability rating according to UL 94
V0 (Housing)
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 50 °C
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Standards/regulations
DIN EN 50178
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice