Product Model

PLC-RSP- 48DC/21

In Stock
Last updated: 2025/4/21
Phoenix Contact PLC-RSP- 48DC/21

Selling Points

  • 1Slim Design: Compact and space-efficient for easy integration into your automation system.
  • 2Efficient Connection: Utilizes V8 adapter for seamless connection to system cabling.
  • 3Safe Isolation: Meets DIN EN 50178 standards for safe isolation between coil and contact.
  • 4High Reliability: RT III sealed relay ensures reliable operation in various environments.
  • 5Versatile Mounting: Designed for DIN rail NS 35/7.5 mounting, suitable for various industrial applications.
Product Details
PLC-RSP- 48DC/21
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Relay Module
Product family
PLC-INTERFACE
Application
Universal
Operating mode
100% operating factor
Mechanical service life
2x 10
Date of last data management
10.10.2023
Overvoltage category
III
Pollution degree
3
Maximum power dissipation for nominal condition
0.44 W
Test voltage (Winding/contact)
4 kV AC (50 Hz, 1 min., winding/contact)
Nominal input voltage U
48 V DC
Input voltage range
37.4 V DC ... 60 V DC
Typical input current at U
9.2 mA
Typical response time
5 ms
Typical release time
8 ms
Protective circuit
Reverse polarity protection; Polarity protection diode Freewheeling diode; Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
1 changeover contact
Type of switch contact
Single contact
Contact material
AgSnO
Maximum switching voltage
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage
5 V (at 100 mA)
Limiting continuous current
6 A
Maximum inrush current
on request
Min. switching current
10 mA (at 12 V)
Interrupting rating (ohmic load) max.
140 W (24 V DC) 20 W (48 V DC) 18 W (60 V DC) 23 W (110 V DC) 40 W (220 V DC) 1500 VA (250 V AC)
Switching capacity
2 A (at 24 V, DC13) 0.2 A (at 110 V, DC13) 0.1 A (at 220 V, DC13) 3 A (at 24 V, AC15) 3 A (at 120 V, AC15) 3 A (at 230 V, AC15)
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Width
6.2 mm
Height
80 mm
Depth
94 mm
Color
green (RAL 6021)
Flammability rating according to UL 94
V0 (Housing)
Degree of protection (Relay base)
IP20 (Relay base)
Ambient temperature (operation)
-40 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Standards/regulations
IEC 60664 IEC 60947-5-1
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice