Selling Points
- 1Efficient Wiring Solution: Compact design for wiring in confined spaces.
- 2High Insulation: Insulating material group I, overvoltage category III, and degree of pollution 3.
- 3Reliable Connections: Push-in connection with lateral conductor entry and additional test pick-off.
- 4Versatile Applications: Suitable for railway, machine building, plant engineering, and process industries.
- 5Durable Construction: Rated for -60 °C ambient temperature and 800 V nominal voltage.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Feed-through terminal block | Product family | PTV |
Area of application | Railway industry
Machine building
Plant engineering
Process industry | Number of positions | 1 |
Number of connections | 2 | Number of rows | 1 |
Potentials | 1 | Article revision | 03 |
Overvoltage category | III | Degree of pollution | 3 |
Maximum power dissipation for nominal condition | 0.77 W | Number of connections per level | 2 |
Nominal cross section | 2.5 mm² | Stripping length | 8 mm ... 10 mm |
Internal cylindrical gage | A3 | Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section rigid | 0.14 mm² ... 4 mm² | Cross section AWG | 26 ... 12 (converted acc. to IEC) |
Conductor cross section flexible | 0.14 mm² ... 4 mm² | Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve) | 0.5 mm² ... 1 mm² | Nominal current | 24 A (at 2.5 mm²) |
Maximum load current | 28 A (with 4 mm² conductor cross section, rigid) | Nominal voltage | 800 V |
Nominal cross section | 2.5 mm² | Conductor cross section rigid | 0.5 mm² ... 4 mm² |
Conductor cross section, rigid [AWG] | 20 ... 12 (converted acc. to IEC) | Conductor cross-section flexible (ferrule without plastic sleeve) | 1.5 mm² ... 2.5 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 1.5 mm² ... 2.5 mm² | Identification | II 2 G Ex eb IIC Gb |
Operating temperature range | -60 °C ... 110 °C | Ex-certified accessories | 1088746 D-PTV 2,5/4
3030721 ATP-ST 4
1204517 SZF 1-0,6X3,5
3022276 CLIPFIX 35-5 |
List of bridges | Plug-in bridge / FBS 2-5 / 3030161
Plug-in bridge / FBS 3-5 / 3030174
Plug-in bridge / FBS 4-5 / 3030187
Plug-in bridge / FBS 5-5 / 3030190
Plug-in bridge / FBS 10-5 / 3030213
Plug-in bridge / FBS 20-5 / 3030226
Plug-in bridge / FBS 50-5 / 3038930 | Bridge data | 20.5 A / 2.5 mm² |
Ex temperature increase | 40 K (20.7 A / 2.5 mm²) | Rated voltage | 550 V |
for bridging with bridge | 550 V | - At bridging between non-adjacent terminal blocks | 352 V |
- At cut-to-length bridging | 275 V | - At cut-to-length bridging with cover | 275 V |
- At cut-to-length bridging with partition plate | 550 V | Rated insulation voltage | 500 V |
output | (Permanent) | Rated current | 20.5 A (2.5 mm²) |
Maximum load current | 24.5 A (4 mm²) | Contact resistance | 0.8 mΩ |
Nominal cross section | 2.5 mm² | Rated cross section AWG | 14 |
Connection capacity rigid | 0.14 mm² ... 4 mm² | Connection capacity AWG | 26 ... 12 |
Connection capacity flexible | 0.14 mm² ... 4 mm² | Connection capacity AWG | 26 ... 12 |
Width | 5.2 mm | End cover width | 2.2 mm |
Height | 50.8 mm | Depth | 35.3 mm |
Depth on NS 35/7,5 | 36.8 mm | Depth on NS 35/15 | 44.3 mm |
Color | green (RAL 6021) | Flammability rating according to UL 94 | V0 |
Insulating material group | I | Insulating material | PA |
Static insulating material application in cold | -60 °C | Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Surface flammability NFPA 130 (ASTM E 162) | passed | Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed | Test voltage setpoint | 9.8 kV |
Result | Test passed | Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Result | Test passed | Short-time withstand current 2.5 mm² | 0.3 kA |
Result | Test passed | Test voltage setpoint | 2 kV |
Result | Test passed | Open side panel | Yes |
Result | Test passed | DIN rail/fixing support | NS 35 |
Result | Test passed | Rotation speed | 10 rpm |
Revolutions | 135 | Conductor cross section/weight | 0.14 mm² / 0.2 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg |
Result | Test passed | Temperature cycles | 192 |
Result | Test passed | Time of exposure | 30 s |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
Spectrum | Service life test category 2, bogie-mounted | Frequency | f |
ASD level | 6.12 (m/s²)²/Hz | Acceleration | 3.12g |
Test duration per axis | 5 h | Test directions | X-, Y- and Z-axis |
Result | Test passed | Pulse shape | Half-sine |
Acceleration | 30g | Shock duration | 18 ms |
Number of shocks per direction | 3 | Test directions | X-, Y- and Z-axis (pos. and neg.) |
Result | Test passed | Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) | Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C | Permissible humidity (operation) | 20 % ... 90 % |
Permissible humidity (storage/transport) | 30 % ... 70 % | Connection in acc. with standard | IEC 60947-7-1 |
Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice