Phoenix Contact PTV 2,5 OG

Selling Points

  • 1High-Voltage Capability: Handles up to 800 V with a nominal current of 24 A.
  • 2Compact Design: Enables wiring in confined spaces with lateral conductor entry.
  • 3Push-in Connection: Easy and secure connection method for solid and flexible conductors.
  • 4Versatile Applications: Suitable for railway, machine building, plant engineering, and process industries.
  • 5Durable Construction: Meets overvoltage category III and degree of pollution 3 standards.
Product Details
PTV 2,5 OG
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Feed-through terminal block
Product family
PTV
Area of application
Railway industry Machine building Plant engineering Process industry
Number of positions
1
Number of connections
2
Number of rows
1
Potentials
1
Article revision
03
Overvoltage category
III
Degree of pollution
3
Maximum power dissipation for nominal condition
0.77 W
Number of connections per level
2
Nominal cross section
2.5 mm²
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm² ... 1 mm²
Nominal current
24 A (at 2.5 mm²)
Maximum load current
28 A (with 4 mm² conductor cross section, rigid)
Nominal voltage
800 V
Nominal cross section
2.5 mm²
Conductor cross section rigid
0.5 mm² ... 4 mm²
Conductor cross section, rigid [AWG]
20 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
1.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
1.5 mm² ... 2.5 mm²
Identification
 II 2 G  Ex eb IIC Gb
Operating temperature range
-60 °C ... 110 °C
Ex-certified accessories
1088746 D-PTV 2,5/4 3030721 ATP-ST 4 1204517 SZF 1-0,6X3,5 3022276 CLIPFIX 35-5
List of bridges
Plug-in bridge / FBS 2-5 / 3030161 Plug-in bridge / FBS 3-5 / 3030174 Plug-in bridge / FBS 4-5 / 3030187 Plug-in bridge / FBS 5-5 / 3030190 Plug-in bridge / FBS 10-5 / 3030213 Plug-in bridge / FBS 20-5 / 3030226 Plug-in bridge / FBS 50-5 / 3038930
Bridge data
20.5 A / 2.5 mm²
Ex temperature increase
40 K (20.7 A / 2.5 mm²)
Rated voltage
550 V
for bridging with bridge
550 V
- At bridging between non-adjacent terminal blocks
352 V
- At cut-to-length bridging
275 V
- At cut-to-length bridging with cover
275 V
- At cut-to-length bridging with partition plate
550 V
Rated insulation voltage
500 V
output
(Permanent)
Rated current
20.5 A (2.5 mm²)
Maximum load current
24.5 A (4 mm²)
Contact resistance
0.8 mΩ
Nominal cross section
2.5 mm²
Rated cross section AWG
14
Connection capacity rigid
0.14 mm² ... 4 mm²
Connection capacity AWG
26 ... 12
Connection capacity flexible
0.14 mm² ... 4 mm²
Connection capacity AWG
26 ... 12
Width
5.2 mm
End cover width
2.2 mm
Height
50.8 mm
Depth
35.3 mm
Depth on NS 35/7,5
36.8 mm
Depth on NS 35/15
44.3 mm
Color
orange (RAL 2003)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Test voltage setpoint
9.8 kV
Result
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Result
Test passed
Short-time withstand current 2.5 mm²
0.3 kA
Result
Test passed
Test voltage setpoint
2 kV
Result
Test passed
Open side panel
Yes
Result
Test passed
DIN rail/fixing support
NS 35
Result
Test passed
Rotation speed
10 rpm
Revolutions
135
Conductor cross section/weight
0.14 mm² / 0.2 kg 2.5 mm² / 0.7 kg 4 mm² / 0.9 kg
Result
Test passed
Temperature cycles
192
Result
Test passed
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Spectrum
Service life test category 2, bogie-mounted
Frequency
f
ASD level
6.12 (m/s²)²/Hz
Acceleration
3.12g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Result
Test passed
Pulse shape
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice