Phoenix Contact PTV 2,5-TWIN WH

Selling Points

  • 1Compact Design: Enables wiring in confined spaces with lateral conductor entry.
  • 2Push-in Connection: Easy and secure connection method for solid and flexible conductors.
  • 3High Surge Voltage: Rated for 8 kV surge voltage, ensuring reliable operation under overvoltage conditions.
  • 4Multiple Applications: Suitable for railway industry, machine building, and plant engineering.
  • 5Durable Construction: Meets UL 94 V0 flammability rating and withstands mechanical tests including bending and tensile forces.
Product Details
PTV 2,5-TWIN WH
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note
The max. load current must not be exceeded by the total current of all connected conductors.
Product type
Multi-conductor terminal block
Product family
PTV
Area of application
Railway industry Machine building Plant engineering Process industry
Number of connections
3
Number of rows
1
Potentials
1
Article revision
02
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
0.77 W
Number of connections per level
3
Nominal cross section
2.5 mm²
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm² ... 1 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
1 mm²
Nominal current
24 A (with 2.5 mm² conductor connection cross section)
Maximum load current
28 A (with 4 mm² conductor cross section, rigid)
Nominal voltage
800 V
Nominal cross section
2.5 mm²
Conductor cross section rigid
0.5 mm² ... 4 mm²
Conductor cross section, rigid [AWG]
20 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
1.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
1.5 mm² ... 2.5 mm²
Identification
 II 2 G  Ex eb IIC Gb
Operating temperature range
-60 °C ... 110 °C
Ex-certified accessories
1088747 D-PTV 2,5/4-TWIN 1083618 DS-PTV 2,5/4 3024481 ATP-ST 6 1204517 SZF 1-0,6X3,5 3022276 CLIPFIX 35-5
List of bridges
Plug-in bridge / FBS 2-5 / 3030161 Plug-in bridge / FBS 3-5 / 3030174 Plug-in bridge / FBS 4-5 / 3030187 Plug-in bridge / FBS 5-5 / 3030190 Plug-in bridge / FBS 10-5 / 3030213 Plug-in bridge / FBS 20-5 / 3030226 Plug-in bridge / FBS 50-5 / 3038930
Bridge data
20.5 A / 2.5 mm²
Ex temperature increase
40 K (21,1 A / 2,5 mm²)
Rated voltage
550 V
for bridging with bridge
550 V
- At bridging between non-adjacent terminal blocks
352 V
- At cut-to-length bridging
275 V
- At cut-to-length bridging with cover
275 V
- At cut-to-length bridging with partition plate
550 V
Rated insulation voltage
500 V
output
(Permanent)
Rated current
20.5 A (2.5 mm²)
Maximum load current
24.5 A (4 mm²)
Contact resistance
0.8 mΩ
Nominal cross section
2.5 mm²
Rated cross section AWG
14
Connection capacity rigid
0.14 mm² ... 4 mm²
Connection capacity AWG
26 ... 12
Connection capacity flexible
0.14 mm² ... 4 mm²
Connection capacity AWG
26 ... 12
Width
5.2 mm
End cover width
2.2 mm
Height
60 mm
Depth
45.7 mm
Depth on NS 35/7,5
47.2 mm
Depth on NS 35/15
54.7 mm
Color
white (RAL 9010)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Result
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Result
Test passed
Short-time withstand current 2.5 mm²
0.3 kA
Result
Test passed
Test voltage setpoint
2 kV
Result
Test passed
Open side panel
Yes
Result
Test passed
DIN rail/fixing support
NS 35
Test force setpoint
1 N
Result
Test passed
Rotation speed
10 rpm
Revolutions
135
Conductor cross section/weight
0.14 mm² / 0.2 kg 2.5 mm² / 0.7 kg 4 mm² / 0.9 kg
Result
Test passed
Temperature cycles
192
Result
Test passed
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Spectrum
Service life test category 2, bogie-mounted
Frequency
f
ASD level
6.12 (m/s²)²/Hz
Acceleration
3.12g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Pulse shape
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice