Product Model

PTVFIX 18X2,5 GN

In Stock
Last updated: 2025/4/17
Phoenix Contact PTVFIX 18X2,5 GN

Selling Points

  • 1Time-saving conductor connection: Tool-free Push-in direct connection technology.
  • 2Flexible mounting options: DIN rail mounting, direct mounting, or adhesive mounting.
  • 3Space-efficient design: Transverse mounting saves up to 50% on DIN rail space.
  • 4High reliability: Meets DIN EN 50274 (VDE 0660-514) shock protection standards.
  • 5Versatile connectivity: Supports conductor cross sections from 0.14 mm² to 4 mm².
Product Details
PTVFIX 18X2,5 GN
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Distributor terminal block
Number of positions
1
Number of connections
18
Number of rows
1
Potentials
1
Article revision
02
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
0.77 W
Number of connections per level
18
Nominal cross section
2.5 mm²
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3 B3
Connection in acc. with standard
IEC 60998-2-2
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
Nominal current
24 A
Maximum load current
32 A (with 4 mm² conductor cross-section)
Maximum total current
The maximum load current of the individual terminal point must not be exceeded.
Nominal voltage
450 V
Nominal cross section
2.5 mm²
Conductor cross section rigid
0.5 mm² ... 4 mm²
Conductor cross section, rigid [AWG]
20 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.75 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.5 mm² ... 2.5 mm²
Width
46.6 mm
Height
28.6 mm
Depth
21.7 mm
Color
green (RAL 6021)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Open side panel
No
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60998-2-2
Mounting type
for snapping onto a DIN rail adapter Direct mounting with flange Free-hanging