Product Model

PTVFIX 6/6X2,5 GY

In Stock
Last updated: 2025/4/18
Phoenix Contact PTVFIX 6/6X2,5 GY

Selling Points

  • 1Time-saving Push-in connections for easy conductor connection.
  • 2High reliability with a nominal voltage of 500 V and nominal current of 24 A.
  • 3Versatile mounting options including DIN rail, direct mounting, and adhesive mounting.
  • 4Clear wiring with eleven different color variants for easy identification.
  • 5Space savings of up to 50% on the DIN rail with transverse mounting.
Product Details
PTVFIX 6/6X2,5 GY
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Note
The maximum load current of a single clamping unit must not be exceeded. For power distribution applications, IEC 60364-4-43.2008; modified + corrigendum Okt. 2008 (DIN VDE 0100-430:2010-10) section 433.2 ff must be observed!
Product type
Distributor terminal block
Number of positions
1
Number of connections
7
Number of rows
1
Article revision
02
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
0.77 W
Service Entrance
yes
Number of connections per level
7
Nominal cross section
2.5 mm²
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3 B3
Connection in acc. with standard
IEC 60998-2-2
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm²
Nominal current
24 A
Maximum load current
32 A (with 4 mm² conductor cross section)
Maximum total current
57 A (with 10 mm² conductor cross section)
Nominal voltage
450 V
Nominal cross section
2.5 mm²
Stripping length
10 mm ... 12 mm
Internal cylindrical gage
A5 B4
Conductor cross section rigid
0.5 mm² ... 10 mm²
Cross section AWG
20 ... 8 (converted acc. to IEC)
Conductor cross section flexible
0.5 mm² ... 10 mm²
Conductor cross section, flexible [AWG]
20 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.5 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.5 mm² ... 6 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm² ... 1.5 mm²
Nominal current
41 A (with 6 mm² conductor cross section)
Maximum load current
57 A (with 10 mm² conductor cross section)
Nominal cross section
6 mm²
Conductor cross section rigid
0.34 mm² ... 4 mm²
Conductor cross section, rigid [AWG]
22 ... 18 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.34 mm² ... 2.5 mm²
Conductor cross section rigid
1 mm² ... 10 mm²
Conductor cross section, rigid [AWG]
18 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
1 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
1 mm² ... 6 mm²
Width
26 mm
Height
28.6 mm
Depth
21.7 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Open side panel
No
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Spectrum
Service life test category 2, bogie-mounted
Frequency
f
ASD level
6.12 (m/s²)²/Hz
Acceleration
3.12g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Pulse shape
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60998-2-2
Mounting type
for snapping onto a DIN rail adapter Direct mounting with flange Free-hanging

Specifications may be subject to change without notice