Product Model
QUINT-HP-UPS/120AC/2.5KVA/PT

Selling Points
- 1High efficiency with >94% efficiency at 100% load and battery charged.
- 2Pure sine wave output for reliable AC load supply.
- 3Robust overload protection with 120% to 150% overload capability in mains, battery, and bypass modes.
- 4Compact design with active cooling for optimal performance.
- 5Wide input voltage range from 100 V AC to 130 V AC with ±2% output voltage tolerance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Note on the battery | For proper operation of the UPS, at least 2 QUINT-HP-BAT/PB/48DC/7.0AH/PT (1133819) battery modules are required. | Input voltage | 100 V AC -10 % / +20 %
110 V AC -10 % / +20 %
120 V AC -10 % / +15 %
130 V AC -15 % / +10 % |
Voltage type of supply voltage | AC | Frequency range (f | 47.5 Hz ... 52.5 Hz
57 Hz ... 63 Hz |
Bypass fuse | 40 A T 250 V | Permissible backup fuse | 40 A (Listed breaker) |
Current consumption | nom. 24 A (100 V AC)
nom. 23.3 A (110 V AC)
nom. 24 A (120 V AC)
nom. 23.4 A (130 V AC)
max. 34.4 A (100 V AC)
max. 31.2 A (110 V AC)
max. 35.4 A (120 V AC)
max. 34.6 A (130 V AC) | Rated short-time current carrying capacity Icw | 6 kA |
Classification according to IEC 62040-3 | VFI-SS-111 | Efficiency | > 94 % (100% load, battery charged)
> 90 % (100% load, battery charged) |
Apparent power | 2500 VA | Real power | 2250 W |
Power factor (cos phi) | 0.9 | Crest factor | 2.5 |
Switch-over time | 0 ms | Connection in parallel | yes
max. 3 |
Connection in series | no | Overload capability Mains operation | 120 % ... 150 % (20 s / 5 s, then switch to bypass operation) |
Overload capability Battery operation | 120 % ... 150 % (20 s / 5 s, then shutdown) | Overload capability Bypass mode | 120 % ... 150 % (for a sustained period / 20 s, then shutdown) |
Rated short-time current carrying capacity Icw | 6 kA | Output voltage | 100 V AC ±2 %
110 V AC ±2 %
120 V AC ±2 %
130 V AC ±2 % |
Form of output voltage | Pure sine | Output current | nom. 20 A (100 V AC)
nom. 18.2 A (110 V AC)
nom. 20.8 A (120 V AC)
nom. 19.2 A (130 V AC) |
Maximum no-load power dissipation | 9 W | Power loss nominal load max. | < 120 W (100% load, battery charged) |
Nominal output frequency | 50 Hz
60 Hz
±0.5 % (Output frequency tolerance) | Electronic current limitation | > 2 x Output: Current nom. (> 200 ms) |
Maximum no-load power dissipation | 9 W | Power loss nominal load max. | 250 W (100% load, battery charged) |
Nominal output frequency | 50 Hz
60 Hz
±0.5 % (Output frequency tolerance) | Total harmonic distortion factor (THD) | < 3 % (linear load)
< 8 % (non-linear load) |
Electronic current limitation | > 2 x Output: Current nom. (> 200 ms) | Input voltage | 48 V DC
max. 60 V DC |
Input current | max. 40 A | Nominal capacity range | 7 Ah ... 200 Ah |
Charging current | max. 10 A | Short-circuit current | 650 A ( |
Connection in parallel | yes
max. 5 (per battery string) | Connection in series | no |
IQ-Technology | yes | Permissible backup fuse | 40 A |
Temperature sensor | yes | Permissible backup fuse | 40 A |
Position | 1.x | Identification | 1.1 (L), 1.2 (N), 1.3 () |
Position marking | 1.1 (L), 1.2 (N), 1.3 () | Connection method | Push-in connection |
rigid | 4 mm² ... 6 mm² | flexible | 4 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 4 mm² | flexible with ferrule with plastic sleeve | 4 mm² |
rigid (AWG) | 10 | Stripping length | 10 mm |
Position | 2.x | Identification | 2.1 (L), 2.2 (N), 2.3 () |
Position marking | 2.1 (L), 2.2 (N), 2.3 () | Connection method | Push-in connection |
rigid | 4 mm² ... 6 mm² | flexible | 4 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 4 mm² | flexible with ferrule with plastic sleeve | 4 mm² |
rigid (AWG) | 10 | Stripping length | 10 mm |
Position | 2.x | Identification | 2.4 (L'), 2.5 (N), 2.6 () |
Position marking | 2.4 (L'), 2.5 (N), 2.6 () | Connection method | Push-in connection |
rigid | 4 mm² ... 6 mm² | flexible | 4 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 4 mm² | flexible with ferrule with plastic sleeve | 4 mm² |
rigid (AWG) | 10 | Stripping length | 15 mm |
Position | 4.x | Identification | 4.1, 4.2; 4.3, 4.4 |
Position marking | 4.1 (+), 4.2 (-), 4.3 (+), 4.4 (-) | Connection method | Push-in connection |
rigid | 6 mm² ... 16 mm² | flexible | 6 mm² ... 16 mm² |
flexible with ferrule without plastic sleeve | 6 mm² ... 16 mm² | flexible with ferrule with plastic sleeve | 6 mm² ... 16 mm² |
rigid (AWG) | 8 ... 6 | Stripping length | 18 mm |
Position | 3.x | Identification | 3.1 ... 3.9 |
Position marking | 3.1 (Alarm), 3.2 (Bat.-Mode), 3.3 (Power Good), 3.4 (Ready), 3.5 (P>Pn), 3.6 (Service Required), 3.7 (Bat.-Start), 3.8 (Remote), 3.9 (SGnd) | Connection method | Push-in connection |
rigid | 0.2 mm² ... 4 mm² | flexible | 0.2 mm² ... 4 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² | flexible with ferrule with plastic sleeve | 0.2 mm² ... 2.5 mm² |
rigid (AWG) | 24 ... 12 | Stripping length | 10 mm |
Interface | Battery module communication interface | Number of interfaces | 1 |
Connection method | RJ45 | Position | 5.x |
Locking | Locking clip | Transmission physics | Twisted-Pair 4x2 |
Interface | Parallel operation communication interface | Number of interfaces | 2 |
Connection method | RJ45 | Position | 5.x |
Locking | Locking clip | Transmission physics | Twisted-Pair 4x2 |
Low signal | Connection to SGnd with < 2.7 kΩ | High signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
Low signal | Connection to SGnd with < 2.7 kΩ | High signal | Open (> 35 kΩ between Remote and SGnd) |
Position | 3.x | Signalization designation | Alarm |
Position marking | 3.1 (Alarm) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Position | 3.x | Signalization designation | Bat.-Mode |
Position marking | 3.2 (Bat.-Mode) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Position | 3.x | Signalization designation | Power Good |
Position marking | 3.3 (Power Good) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Position | 3.x | Signalization designation | Ready |
Position marking | 3.4 (Ready) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Position | 3.x | Signalization designation | P>P |
Position marking | 3.5 (P>Pn) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Position | 3.x | Signalization designation | Service Required |
Position marking | 3.6 (Service Required) | Switching output | Transistor output, active |
Output voltage | 24 V | Continuous load current | ≤ 20 mA |
Function | Signal ground | Reference potential | For signal inputs and signal outputs |
Product type | AC UPS | Product family | QUINT AC UPS |
Article revision | 02 | Protection class | I |
Overvoltage category | II | Pollution degree | 3 |
Width | 188 mm | Height | 240 mm |
Depth | 143 mm | Diameter | 5.5 mm |
Installation distance right/left | 0 mm / 0 mm | Installation distance top/bottom | 50 mm / 50 mm |
Mounting type | Wall mounting | Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 60 °C (> 50 °C: 2,5 % / K) | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 4000 m (> 1000 m: 3 % / 1000 m) | Max. permissible relative humidity (operation) | ≤ 95 % |
Shock | 30g in each direction, according to IEC 60068-2-27 | Vibration (operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
Identification | UL/C-UL Recognized UL 1778 | Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | Interference emission | Noise emission |
Noise immunity | Immunity | Conducted noise emission | EN 62040-02 (Class C2) |
Standards/regulations | EN 61000-4-2 | Contact discharge | ± 6 kV |
Discharge in air | ± 8 kV | Comments | Criterion A |
Standards/regulations | EN 61000-4-3 | Frequency range | 80 MHz ... 6 GHz |
Test field strength | 10 V/m | Comments | Criterion A |
Standards/regulations | EN 61000-4-4 | Input | ± 2 kV
± 2 kV |
Output | ± 2 kV | Signal | ± 2 kV
± 2 kV (Communication parallel operation, battery module) |
Comments | Criterion A | Standards/regulations | EN 61000-4-5 |
Signal | 1 kV (asymmetrical) | Comments | Criterion B |
Input/Output | ± 1 kV (symmetrical)
± 2 kV (asymmetrical) | Standards/regulations | EN 61000-4-6 |
Frequency range | 0.15 MHz ... 80 MHz | Signal | 10 V (asymmetrical) |
Comments | Criterion A | Standards/regulations | EN 61000-4-8 |
Frequency | 60 Hz | Signal | 30 A/m |
Comments | Criterion A | Standards/regulations | EN 61000-4-13 |
Comments | Criterion A | Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Specifications may be subject to change without notice