Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Nominal input voltage range
100 V AC ... 240 V AC
Input voltage range
85 V AC ... 264 V AC 90 V DC ... 350 V DC
Input voltage range AC
85 V AC ... 264 V AC
Input voltage range DC
90 V DC ... 350 V DC
Voltage type of supply voltage
AC/DC
Inrush current
< 15 A (3.2 A
Inrush current integral (I
3.2 A
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Mains buffering time
> 30 ms (120 V AC) > 35 ms (230 V AC)
Current consumption
approx. 4.76 A (120 V AC) 2.3 A (230 V AC)
Nominal power consumption
524 W
Protective circuit
Transient surge protection; Varistor
Typical response time
< 1 s
Input fuse
12 A (slow-blow, internal)
Permissible backup fuse
B10 B16
Recommended breaker for input protection
10 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE
< 3.5 mA
Efficiency
> 90 %
Nominal output voltage
48 V DC ±1 %
Setting range of the output voltage (U
30 V DC ... 56 V DC
Nominal output current (I
10 A (up to 60 °C)
Output current limit
13 A (approx. I
POWER BOOST (I
13 A
Derating
60 °C (2.5 %/K)
Feedback voltage resistance
60 V DC
Protection against overvoltage at the output (OVP)
≤ 60 V DC
Max. capacitive load
unlimited
Control deviation
< 1 % (change in load, static 10 % ... 90 %) < 5 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %)
Residual ripple
< 20 mV
Output power
480 W
Peak switching voltages nominal load
< 50 mV
Maximum no-load power dissipation
< 5 W
Power loss nominal load max.
< 56 W
Rise time
< 2 ms (U
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Output description
U
Maximum switching voltage
≤ 24 V
Output voltage
+ 24 V DC
Maximum inrush current
≤ 40 mA
Continuous load current
≤ 40 mA
Output description
Relay contact, U
Maximum switching voltage
≤ 30 V AC/DC
Maximum inrush current
≤ 1 A
Continuous load current
≤ 1 A
Connection method
Screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
6 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
4 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
10
Stripping length
7 mm
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Connection method
Screw connection
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Stripping length
7 mm
Screw thread
M4
Tightening torque, min
1.2 Nm
Tightening torque max
1.5 Nm
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Screw thread
M4
Tightening torque, min
1.2 Nm
Tightening torque max
1.5 Nm
Types of signaling
LED Active switching output Relay contact
Status display
"DC OK" LED green
Note on status display
U
Status display
"DC OK" LED green
Note on status display
U
Number of phases
1.00
Insulation voltage input/output
4 kV AC (type test) 2 kV AC (routine test)
Insulation voltage output / PE
500 V DC (routine test)
Insulation voltage input / PE
3.5 kV AC (type test) 2 kV AC (routine test)
Product type
Power supply
Product family
QUINT POWER
MTBF (IEC 61709, SN 29500)
> 500000 h
Protection class
I (with PE connection)
Degree of pollution
2
Width
157 mm
Height
130 mm
Depth
125 mm
Width
122 mm
Height
130 mm
Depth
160 mm
Mounting type
DIN rail mounting
Assembly note
alignable: horizontally 0 mm, vertically 50 mm
Mounting position
horizontal DIN rail NS 35, EN 60715
Housing material
Metal
Type of housing
AluNox (AlMg1)
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Climatic class
3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)
95 % (at 25 °C, non-condensing)
Shock
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min.
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Standard - Electrical safety
EN 60950-1/VDE 0805 (SELV) EN 61558-2-17
Standard - Equipment safety
GS (tested safety)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
EN 50178
Standard – Safety extra-low voltage
EN 60950-1 (SELV) EN 60204 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard - Safety of transformers
EN 61558-2-17
EN 62477-1
III
Shipbuilding approval
DNV GL (EMC A), ABS
UL approvals
UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950-1
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission
EN 61000-6-3 EN 61000-6-4
EMC requirements for noise immunity
EN 61000-6-1 EN 61000-6-2
Standards/regulations
EN 61000-4-2
Housing
Level 4
Contact discharge
8 kV
Discharge in air
15 kV
Comments
Criterion B
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m
Comments
Criterion A
Standards/regulations
EN 61000-4-4
Input
4 kV (level 4 - asymmetrical: conductor to ground)
Output
2 kV (level 3 - asymmetrical: conductor to ground)
Signal
1 kV (level 1 - asymmetrical: conductor to ground)
Comments
Criterion B
Standards/regulations
EN 61000-4-5
Input
4 kV (inst. class 4 - asymmetrical: conductor to ground) 2 kV (inst. class 4 -symmetrical: conductor to conductor)
Output
0.5 kV (level 1 - asymmetrical: conductor to ground) 0.5 kV (level 1 - symmetrical: conductor to conductor)
Signal
1 kV (level 2 - asymmetrical: conductor to ground)
Comments
Criterion B
Standards/regulations
EN 61000-4-6
I/O/S
Level 3 - asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V
Standards/regulations
EN 61000-4-11
Standards/regulations
EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential

Specifications may be subject to change without notice