Product Model

QUINT-PS/24DC/24DC/10/CO

In Stock
Last updated: 2025/4/21
Phoenix Contact QUINT-PS/24DC/24DC/10/CO

Selling Points

  • 1Regulated Output Voltage: Provides a stable 24 V DC output voltage with a setting range of 18 V to 29.5 V DC.
  • 2High Current Capacity: Delivers 10 A of output current with an optional boost to 12.5 A and up to 60 A with SFB technology.
  • 3Wide Input Voltage Range: Operates with input voltages from 18 V to 32 V DC, ensuring flexibility in various industrial environments.
  • 4Advanced Safety Features: Equipped with transient surge protection, reverse polarity protection, and an internal 25 A fuse for device protection.
  • 5Compact Design: Compact size (48 mm x 130 mm x 125 mm) with a net weight of 0.9 kg, ideal for DIN rail mounting in industrial settings.
Product Details
QUINT-PS/24DC/24DC/10/CO
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Nominal input voltage range
24 V DC
Input voltage range
18 V DC ... 32 V DC
Extended input voltage range in operation
14 V DC ... 18 V DC (Derating)
Wide-range input
no
Input voltage range DC
18 V DC ... 32 V DC 14 V DC ... 18 V DC (Consider derating during operation)
Voltage type of supply voltage
DC
Inrush current
typ. 15 A
Inrush current integral (I
< 2.7 A
Mains buffering time
typ. 12 ms (24 V DC)
Current consumption
14 A (24 V, I
Reverse polarity protection
≤ yes30 V DC
Protective circuit
Transient surge protection; Varistor
Input fuse
25 A (device protection)
Recommended breaker for input protection
16 A ... 20 A (Characteristics B, C, D, K)
Efficiency
> 92 %
Output characteristic
U/I
Nominal output voltage
24 V DC ±1 %
Setting range of the output voltage (U
18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (I
10 A (-25 °C ... 60 °C)
POWER BOOST (I
12.5 A (-25 °C ... 40 °C permanent, U
Selective Fuse Breaking (I
60 A (12 ms)
Magnetic circuit breaker tripping
B2 / B4 / B6 / C2 / C4
Derating
60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance
35 V DC
Protection against overvoltage at the output (OVP)
< 35 V DC
Max. capacitive load
unlimited
Active current limitation
Approx. 18 A
Control deviation
< 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %)
Residual ripple
< 20 mV
Output power
240 W
Peak switching voltages nominal load
< 10 mV
Maximum no-load power dissipation
1.6 W
Power loss nominal load max.
24 W
Rise time
< 2 ms (U
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Output description
U
Switching voltage range
18 V DC ... 24 V DC
Maximum inrush current
< 20 mA (short-circuit-proof)
Output description
I
Switching voltage range
18 V DC ... 24 V DC
Maximum inrush current
< 20 mA (short-circuit-proof)
Output description
U
Switching voltage range
18 V DC ... 24 V DC
Maximum inrush current
≤ 20 mA (short-circuit-proof)
Output description
Relay
Output voltage
≤ 30 V AC/DC
Maximum inrush current
≤ 100 mA
Connection method
Screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
8 mm
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Connection method
Screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
7 mm
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Types of signaling
LED Active switching output Relay contact
Status display
"DC OK" LED green
Color
green
Status display
"BOOST" LED yellow/I
Color
yellow
Note on status display
LED on
Status display
LED "U
Color
yellow
Note on status display
LED on
Note on status display
U Contact closed
Number of phases
1.00
Insulation voltage input/output
1.5 kV (type test) 1 kV (routine test) 1 kV (type test)
Product type
DC/DC converters
Product family
QUINT POWER
MTBF (IEC 61709, SN 29500)
> 763000 h (40 °C)
Article revision
04
Protection class
III
Degree of pollution
2
Width
48 mm
Height
130 mm
Depth
125 mm
Installation distance right/left
0 mm / 0 mm (≤ 70 °C)
Installation distance right/left (active)
15 mm / 15 mm (≤ 70 °C)
Installation distance top/bottom
50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (active)
50 mm / 50 mm (≤ 70 °C)
Width
122 mm
Height
130 mm
Depth
51 mm
Mounting type
DIN rail mounting
Assembly note
alignable: P
Mounting position
horizontal DIN rail NS 35, EN 60715
With protective coating
yes
Housing material
Metal
Type of housing
Aluminum (AlMg3)
Hood version
Galvanized sheet steel, free from chrome (VI)
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Ambient temperature (start-up type tested)
-40 °C
Climatic class
3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)
100 % (at 25 °C, non-condensing)
Shock
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min.
Temp code
T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K)
Rail applications
EN 50121-4 EN 50155
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard - Electrical safety
EN 60950-1/VDE 0805 (SELV)
Standard – Safety extra-low voltage
EN 60950-1 (SELV) EN 60204 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Shipbuilding approval
DNV GL (EMC B)
UL approvals
UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950-1 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
EMC requirements for noise emission
EN 61000-6-3 EN 61000-6-4
EMC requirements for noise immunity
EN 61000-6-1 EN 61000-6-2
Standards/regulations
EN 61000-4-2
Contact discharge
8 kV (Test Level 4)
Discharge in air
15 kV (Test Level 4)
Comments
Criterion A
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m
Frequency range
1 GHz ... 2 GHz
Test field strength
10 V/m
Frequency range
2 GHz ... 3 GHz
Test field strength
10 V/m
Comments
Criterion A
Standards/regulations
EN 61000-4-4
Input
2 kV (Test Level 3 - asymmetrical)
Output
2 kV (Test Level 3 - asymmetrical)
Signal
2 kV (Test Level 4 - asymmetrical)
Comments
Criterion A
Standards/regulations
EN 61000-4-5
Input
0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical)
Output
0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical)
Signal
1 kV (Test Level 2 - asymmetrical)
Comments
Criterion B
Standards/regulations
EN 61000-4-6
I/O/S
asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V (Test Level 3)
Standards/regulations
EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected by the device itself.

Specifications may be subject to change without notice