Product Model
QUINT-PS/3AC/24DC/ 5

Selling Points
- 1Ensures quick and cost-effective system protection by tripping at six times the nominal current.
- 2Reports critical operating states before errors occur, enhancing system availability.
- 3Covers all ranges between 5 V DC and 56 V DC for versatile application.
- 4Provides a static power reserve for reliable starting of heavy loads.
- 5Operates with an efficiency of >89% at 400 V AC and nominal values.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Nominal input voltage range | 3x 400 V AC ... 500 V AC | Input voltage range | 3x 320 V AC ... 575 V AC
2x 360 V AC ... 575 V AC
450 V DC ... 800 V DC |
Voltage type of supply voltage | AC/DC | Inrush current | < 15 A (typical) |
Inrush current integral (I | < 1 A | AC frequency range | 45 Hz ... 65 Hz |
Frequency range DC | 0 Hz | Mains buffering time | > 20 ms (400 V AC)
> 30 ms (500 V AC) |
Current consumption | 3x 0.8 A (400 V AC)
3x 0.7 A (500 V AC)
0.2 A (600 V DC) | Nominal power consumption | 268 VA |
Protective circuit | Transient surge protection; Varistor, gas-filled surge arrester | Power factor (cos phi) | 0.5 |
Typical response time | < 0.06 s | Permissible backup fuse | B6 B10 B16 AC: |
Permissible DC backup fuse | DC: Connect a suitable fuse upstream | Recommended breaker for input protection | 6 A ... 16 A (AC: Characteristics B, C, D, K) |
Discharge current to PE | < 3.5 mA | Efficiency | > 89 % (at 400 V AC and nominal values) |
Output characteristic | U/I | Nominal output voltage | 24 V DC ±1 % |
Setting range of the output voltage (U | 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) | Nominal output current (I | 5 A (-25 °C ... 60 °C, U |
POWER BOOST (I | 7.5 A (-25 °C ... 40 °C permanent, U | Selective Fuse Breaking (I | 30 A (12 ms) |
Magnetic circuit breaker tripping | B2 / B4 / C2 | Derating | 60 °C ... 70 °C (2.5 %/K) |
Feedback voltage resistance | max. 35 V DC | Protection against overvoltage at the output (OVP) | < 35 V DC |
Residual ripple | < 20 mV | Output power | 120 W |
Peak switching voltages nominal load | < 20 mV | Maximum no-load power dissipation | 4 W |
Power loss nominal load max. | 14 W | Rise time | < 0.04 s (U |
Connection in parallel | yes, for redundancy and increased capacity | Connection in series | yes |
Output description | U | Switching voltage range | 18 V DC ... 24 V DC |
Maximum inrush current | ≤ 20 mA (short-circuit-proof) | Continuous load current | ≤ 20 mA |
Output description | Relay contact, U | Maximum switching voltage | 30 V AC/DC
24 V DC |
Maximum inrush current | 0.5 A
1 A | Continuous load current | ≤ 1 A |
Output description | I | Switching voltage range | 18 V DC ... 24 V DC |
Output voltage | + 24 V DC | Maximum inrush current | ≤ 20 mA (short-circuit-proof) |
Continuous load current | ≤ 20 mA | Connection method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 20 | Conductor cross section AWG max. | 12 |
Stripping length | 7 mm | Screw thread | M3 |
Tightening torque, min | 0.5 Nm | Tightening torque max | 0.6 Nm |
Connection method | Pluggable screw connection | Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² | Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² | Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 12 | Stripping length | 7 mm |
Screw thread | M3 | Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm | Connection method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 20 | Conductor cross section AWG max. | 12 |
Screw thread | M3 | Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm | Types of signaling | LED
Active switching output
Relay contact |
Operating voltage display | Green LED | Status display | U |
Note on status display | U | Status display | U |
Note on status display | U | Status display | I |
Number of phases | 3.00 | Insulation voltage input/output | 4 kV AC (type test)
2 kV AC (routine test) |
Insulation voltage output / PE | 500 V DC (routine test) | Insulation voltage input / PE | 3.5 kV AC (type test)
2 kV AC (routine test) |
Product type | Power supply | Product family | QUINT POWER |
MTBF (IEC 61709, SN 29500) | > 1290000 h (25 °C)
> 680000 h (40 °C)
> 290000 h (60 °C) | Article revision | 06 |
Protection class | I | Degree of pollution | 2 |
Width | 40 mm | Height | 130 mm |
Depth | 125 mm | Width | 122 mm |
Height | 130 mm | Depth | 43 mm |
Assembly note | alignable: P | Mounting position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | no | Housing material | Metal |
Hood version | Galvanized sheet steel, free from chrome (VI) | Side element version | Aluminum |
Degree of protection | IP20 | Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C | Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | 5000 m | Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min. | Temp code | T4A (-25 ... +60 °C) |
Rail applications | EN 50121-4
EN 50121-3-2 | Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard - Electrical safety | IEC 61010-2-201 (SELV) | Standard - Equipment safety | GS (tested safety) |
Standard - Approval for medical use | IEC 60601-1, 2 x MOOP | Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Safety extra-low voltage | IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV) | Standard - Safe isolation | IEC 61010-2-201 |
Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-1 | Standard - surge resistance | VDE 0160 (curve W2) |
Approval - requirement of the semiconductor industry with regard to mains voltage dips | SEMI F47-0706 Compliance Certificate | EN 62477-1 | III |
CSA | CAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01 | Shipbuilding approval | DNV GL (EMC A), ABS, LR, RINA, NK, BV |
UL approvals | UL Listed UL 508
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net)
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location) | Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | EMC requirements for noise emission | EN 61000-6-3
EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1
EN 61000-6-2 | Standards/regulations | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) | Discharge in air | 15 kV (Test Level 4) |
Comments | Criterion A | Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz | Test field strength | 20 V/m (Test Level 3) |
Frequency range | 1 GHz ... 2 GHz | Test field strength | 10 V/m (Test Level 3) |
Frequency range | 2 GHz ... 3 GHz | Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A | Standards/regulations | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) | Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) | Comments | Criterion A |
Standards/regulations | EN 61000-4-5 | Input | 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical)
0.5 kV (Test Level 1 - asymmetrical) | Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B | Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical | Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A | Voltage | 10 V (Test Level 3) |
Standards/regulations | EN 61000-6-3 | Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Specifications may be subject to change without notice