Phoenix Contact RIF-1-RPT-LDP-12DC/1IC

Selling Points

  • 1DIN Rail Mounting: Easily integrate into your industrial automation setup with DIN rail mounting.
  • 212V DC Coil: Compatible with 12V DC power supply for reliable operation.
  • 3SPST Configuration: Single-pole, single-throw (SPST) relay design for precise control.
  • 4High Reliability: Built with high-quality components for long-lasting performance.
  • 5Compliant with Industry Standards: Meets or exceeds industry standards for safety and performance.
Product Details
RIF-1-RPT-LDP-12DC/1IC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Notes on operation
FBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Product type
Relay Module
Product family
RIFLINE complete
Application
high inrush currents
Operating mode
100% operating factor
Mechanical service life
3x 10
Date of last data management
15.10.2024
Article revision
04
Insulation
Safe isolation, reinforced insulation
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
0.41 W
Test voltage (Winding/contact)
4 kV AC (50 Hz, 1 min., winding/contact)
Rated insulation voltage
250 V AC
Rated surge voltage
6 kV
Nominal input voltage U
12 V DC
Input voltage range
9.6 V DC ... 16.8 V DC (20 °C)
Input voltage range in reference to U
see diagram
Drive and function
monostable
Drive (polarity)
polarized
Typical input current at U
34 mA
Typical response time
8 ms
Typical release time
10 ms
Coil voltage
12 V DC
Protective circuit
Surge protection; Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
1 N/O contact
Type of switch contact
Single contact
Contact material
AgSnO
Maximum switching voltage
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage
12 V (100 mA)
Limiting continuous current
6 A 10 A (Value is permissible if connections 11 and 21, as well as connections 14 and 24 are bridged.)
Maximum inrush current
80 A (20 ms) 130 A (peak, at capacitive load, 230 V AC, 24 μF)
Min. switching current
100 mA (12 V DC)
Interrupting rating (ohmic load) max.
264 W (at 24 V DC, observe contact derating) 58 W (at 48 V DC) 48 W (at 60 V DC) 50 W (at 110 V DC) 80 W (at 220 V DC) 2750 VA (at 250 V AC, observe contact derating)
Switching capacity min.
1200 mW
Utilization category CB Scheme (IEC 60947-5-1)
AC15, 6 A/250 V (N/O contact) DC13, 2 A/24 V (N/O contact)
Connection method
Push-in connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 1.5 mm²
Conductor cross section flexible
0.14 mm² ... 1.5 mm² 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG
26 ... 16 (solid) 26 ... 16 (flexible)
Diameter
3.2 mm
Width
16 mm
Height
96 mm
Depth
75 mm
Color
gray (RAL 7042)
Degree of protection (Relay)
RT II (Relay)
Degree of protection (Relay base)
IP20 (Relay base)
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 2000 m
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Standards/regulations
IEC 60947-5-1
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice